Search ▸ Agenda item attachment
An application was received from Joseph Correia representing Central Rock Gym and F45, requesting permission for a projecting blade sign at the premises numbered 20 Brattle Street approval has been received from Inspectional Services, Department of Public Works, Community Development Department and abutter response has been received
⚠ This document is a scan; its text was recovered by optical character recognition and may contain errors. The original PDF is authoritative.
City of Cambridge, MA
09/29/2022
180606
Sign/Awning Permit
Status: Active
Date Created: Jun 14, 2022
Primary Location
Applicant
20 Brattle St
Joseph Correia
[email removed]
Cambridge, MA 02138
458 Main Street
Owner:
WILMINGTON, MA 01887
[phone removed]
HARVARD COLLECTION LLC
410 PARK AVE., SUITE 1220 NEW YORK, NY 10022
General Information
What option best describes this application?
Sign(s)
Description of Proposed Work
Sign 1: (QTY 1) Fabricated Aluminum LED Lit Triangular Blade Sign
Sign 2: (QTY 1) 2" Deep Internally LED Lit Stainless Steel Letters Mounted to Aluminum Backer
Estimated Cost of Sign(s) in dollars
19,600
Describe any existing signs or awnings that will remain (including the size of the remaining signs/awnings).
N/A
Cambridge City Council approval may be required.
Will one or more of the proposed signs extend six (6) inches into the public sidewalk?
Yes
You must submit a Projected Sign Application and Abutter's
Form
(https://viewpointcloud.blob.core.windows.net/profile-
pictures/City_Clerk_Sign_Awning_Application_Wed_Jan_02_2019_15:28:46_GMT+0000_(Coordinated_Universal_Time).pdf)
to the City Clerk's Office.
Sign Information
Sign Text
Sign 1: Blade Sign W/ Tenant Names
Illumination
Type of Sign
Internal
Projecting
Width of Sign (feet)
Height of Sign (feet)
2
7
Area of Sign (square feet)
24
Height from the ground to the top of the sign (feet)
19.125
Height from the ground to bottom of the sign (feet)
12.125
Weight of the sign (Ibs)
Sign Material
200
Aluminum
Projection from the Building (inches)
22.5
Width of Building Facade for Associated Use (feet)
176.5
Is the sign an accessory to a first floor store?
Yes
Sign Text
Sign 2: Channel Letters Sign - "20 Brattle"
Illumination
Type of Sign
Internal
Projecting
Width of Sign (feet)
Height of Sign (feet)
5.075
2.25
Area of Sign (square feet)
7.35
Height from the ground to the top of the sign (feet)
15.05
Height from the ground to bottom of the sign (feet)
12.8
Weight of the sign (lbs)
Sign Material
210
Stainless Steel
Projection from the Building (inches)
2
Width of Building Facade for Associated Use (feet)
176.5
Is the sign an accessory to a first floor store?
Yes
Contractor
Contractor Name
Boston Building Wraps Inc
Address
458 Main Street (CORNER OF KIRK ST AND MAIN) Wilmington MA 01887
Telephone
E-mail
[phone removed]
[email removed]
License Expiration Date
License Number
02/13/2024
188440
Contractor's Signature
Date
Signature of Licensed Contractor
06/14/2022
Joseph A. Correia
Community Development Approval
Sign conforms to requirements of Article 7.000
Sign requires a variance from the Board of Zoning Appeal
Comments
Exempt under Article 7.000
City Clerk Internal
Bond Number
Attachments
pdf 1121_67 The Abbot - 20 Brattle St - Exterior Signage-r5.pdf
Uploaded by Joseph Correia on Jun 14, 2022 at 11:34 am
pat Abbot - 1121_67 Abbot Exterior_ Permitting Letter of Approval (2) (RC approved 6-2-2022).pdf
Uploaded by Joseph Correia on Jun 14, 2022 at 11:30 am
pdf 2022-03-30_15-05_Wed_Mar_30_2022_15-07-36.pdf
Uploaded by Joseph Correia on Jun 14, 2022 at 11:29 am
paf Abbot - 1121_67 Abbot Exterior_ Permitting Letter of Approval (2) (RC approved 6-2-2022).pdf
Uploaded by Joseph Correia on Jun 14, 2022 at 11:29 am
p02022-03-3015-WedMar30202215-08-13pd
Uploaded by Joseph Correia on Jun 14, 2022 at 11:32 am
pdf Joe Correia Jr. License (2_15_22 - 9_6_2023) (1).pdf
Uploaded by Joseph Correia on Jun 14, 2022 at 11:35 am
pdf Abbot - City Clerk Sign Awning Application.pdf
Uploaded by Joseph Correia on Jun 14, 2022 at 11:36 am
pdf S101 stamped.pdf
Uploaded by Joseph Correia on Jun 21, 2022 at 12:24 pm
pdf BBW - Abbot TFM Calculations Stamped.pdf
Uploaded by Joseph Correia on Jun 21, 2022 at 12:24 pm
pdf 20 Brattle St CNA conforming wall sign.paf
Uploaded by Sarah Burks on Sep 28, 2022 at 5:35 pm
History
Date
Activity
Jun 14, 2022 at 11:04 am
Joseph Correia started a draft of Record 180606
Joseph Correia added attachment 2022-03-30_15-06_Wed_Mar_30_2022_15-08-13.pdf to Record 180606
Jun 14, 2022 at 11:32 am
Joseph Correia added attachment Joe Correia Jr. License (2_15_22 - 9_6_2023) (1).pdf to Record 180606
Jun 14, 2022 at 11:35 am
Activity
Date
Joseph Correia added attachment Abbot - City Clerk Sign Awning Application.pdf to Record 180606
Jun 14, 2022 at 11:36 am
Joseph Correia submitted Record 180606
Jun 14, 2022 at 11:37 am
approval step Review for Completenesswas assigned to Branden Vigneault on Record 180606
Jun 14, 2022 at 11:37 am
Joseph Correia added attachment S101 stamped.pdf to Record 180606
Jun 21, 2022 at 12:24 pm
Joseph Correia added attachment BBW - Abbot TFM Calculations Stamped.pdf to Record 180606
Jun 21, 2022 at 12:24 pm
Branden Vigneault approved approval step Review for Completeness on Record 180606
Jul 8, 2022 at 4:05 pm
Jul 8, 2022 at 4:05 pm
approval step Historical Commissionwas assigned to Sarah Burks on Record 180606
Jul 8, 2022 at 4:05 pm
approval step Community Development Plan Reviewwas assigned to Daniel Messplay on Record 180606
Jul 8, 2022 at 4:05 pm
approval step Department of Public Works Reviewwas assigned to Brian McLane on Record 180606
Brian McLane approved approval step Department of Public Works Review on Record 180606
Jul 12, 2022 at 8:37 am
Daniel Messplay approved approval step Community Development Plan Review on Record 180606
Sep 7, 2022 at 5:07 pm
Sep 28, 2022 at 5:35 pm
Sarah Burks added attachment 20 Brattle St CNA conforming wall sign.pdf to Record 180606
Sep 28, 2022 at 5:37 pm
Sarah Burks approved approval step Historical Commission on Record 180606
Sep 28, 2022 at 5:37 pm
approval step City Clerk Reviewwas assigned to Lori Perez on Record 180606
Timeline
Status
Assignee
Due Date
Label
Completed
Activated
Branden Vigneault -
Jun 14,2022 at 11:37 am
Jul 8, 2022 at 4:05 pm
Complete
Review for Completeness
Brian McLane
Jul 12, 2022 at 8:37 am
Department of Public Works Review
Jul 8, 2022 at 4:05 pm
Complete
V
Daniel Messplay
Jul 8, 2022 at 4:05 pm
Complete
Sep 7, 2022 at 5:07 pm
Community Development Plan Review
Sarah Burks
Sep 28, 2022 at 5:37 pm
Historical Commission
Complete
Jul 8, 2022 at 4:05 pm
V
Lori Perez
Active
Sep 28, 2022 at 5:37 pm
City Clerk Review
V
Inactive
City Council Approval
V
Inactive
Bond
V
-
Inactive
-
Sign Permit Fee
Inactive
Building Inspector Review
-
-
Inactive
Sign Permit
The Abbot
Building
20 Brattle Street.
Exterior Sign
CITY OF CAMBRIDGE
INSTRUCTIONS FOR OBTAINING PERMISSION FOR PERMANENT SIGNS
AND AWNINGS THAT PROJECT OVER THE PUBLIC WAY MORE THAN SIX
INCHES
1. Complete the Building (Sign) Permit Application on line at the Inspectional Service Department or
on a personal computer. Inspectional Services Department is located at 831 Massachusetts Avenue,
[phone removed]. Items that must be scanned and attached to online application:
•
Sketch or drawing of sign or awning
Copy of sign company's contract
• Insurance
2. Projected Sign Application and Abutter Forms are available at City Clerk's Office, Room 103 City
Hall, 795 Massachusetts Avenue, [phone removed].
3. Complete application. Application must be signed by business owner and property owner black ink
only. You must measure and state the distance by which the sign or structure will project over the public
way. This application is signed under the pains and penalties of perjury. If you have difficulty
ascertaining the distance, you may wish to use a surveyor. Complete the abutter forms.
After completing steps (1) - (3), file the application with the City Clerk.
The completed application can be dropped off at the City Clerk's Office or e-mailed to
Iperez@cambridgema.gov.
4 The Clerk will place the application on the agenda for a City Council meeting for its consideration.
• During the months of September through June, the City Council meets every Monday at 5:30 p.m.
except for Monday holidays. During July and August, the City Council holds one summer meeting.
Applications must be received at the City Clerk's office on the Thursday prior to the Monday meeting.
• After the City Council has approved the petition, the City Clerk will send the petitioner an unexecuted
bond form.
5. Petitioner must have the bond form executed by a Surety Company and then return it to this office.
6. When the executed bond is returned to the City Clerk's Office, the City Clerk will approve the application
that bond is acceptable. ISD will issue a building permit to the petitioner, so long as all building permit
requirements have been met. The petitioner can obtain the sidewalk obstruction permit from DP W.
Revised December 11, 2017
OFFICE OF THE CITY CLERK
CAMBRIDGE CITY HALL, 795 MASSACHUSETTS AVENUE
CAMBRIDGE, MASSACHUSETTS 02139
PHONE [phone removed]
FAX [phone removed]
PAULA M. CRANE
DONNA P. LOPEZ
CITY CLERK
DEPUTY CITY CLERK
June 3
→ 2022
Cambridge,
To the Honorable, the City Council of the City of Cambridge:
EACH PETITION MUST BE ACCOMPANIED BY A DRAWING OF PROPOSED SIGN, INDICATING DESIGN AND
DIMENSIONS AND LOCATION ON PREMISES.
The undersigned respectfully prays that Boston Building Wraps, Inc.
(NAME OF BUSINESS)
be granted permit to erect a sign of the following specifications in front of premises located at
20 Brattle Street, Cambridge, MA 02138
(ADDRESS)
Type of Sign: 847424225*2 SIDED ALUMINUM BLADE SIGN WITH STEEL POSTS AND PLATES, STENGIL CUT HEADER ON CABINET WITH LIT COPY, 2 FACES POLYCARBONATE W VINYL COPY, INTERNAL POWER SUPLY, LED
(state whether electric or otherwise and material used in construction)
Reading matter to go on Sign:
"The Abbot" LED Letters. There will be 4 tenant / company logos on this LED Lit Blade Sign.
2 Tenant Names TBD. "Central Rock Gym" Logo & "F45" Logo are the other 2. Also an address "20 Brattle Sign"
. 21" w x 7' h. 22.5" Deep.
Size:
Weight: Approx. 200/210 Pounds
Public Way
Obstruction:
в. 145.8"
A.22.5"
(Give exact distance sign is to extend over sidewalk) (Also exact distance from bottom of sign to sidewalk)
Top: 230.2"
Height Above Grade: Bottom: 145.8"
NOTICE - REGULATIONS
Section 1212.0 State Building Code - Projecting Signs]
[Section 12.08.010 Municipal Code - Encroachments onto Streets]
• A projecting sign shall be constructed wholly of incombustible materials.
• All signs must meet requirements of Zoning Ordinances and Building Code.
• Note: Section 12.12.220 provides in part "every owner who maintains a... structure in or over a street... Shall do so only or
the condition that such maintenance shall be considered as an agreement on his part to keep the same and the covers thereof ir
good repair and condition, at all times during his ownership, and to indemnify and save harmless the City against any and all
damages, cost or expenses which it may sustain, or be required to pay by reason of such.. structure."
PROPERTY OWNER OR AUTHORIZED AGENT HEREBY STATES THAT INFORMATION IS TRUE TO THE BEST OF HIS/HER
KNOWLEDGE AND UNDERSTANDING UNDER PAINS AND PENALTY OF PERJURY.
1919 Gallows Rd., Suite 1000, Vienna, VA 22182 / [phone removed]
(Property owner or authorized agent)
(Tel. No.)
• (Address)
Same as Owner
(Tel. No.)
(Business owner)
(Address)
The Abbot
Building
OFFICE OF THE CITY CLERK
CAMBRIDGE CITY HALL, 795 MASSACHUSETTS AVENUE
20 Brattle St.
CAMBRIDGE, MASSACHUSETTS 02139
Exterior Signs
PHONE [phone removed]
FAX [phone removed]
TTY/TDD [phone removed]
PAULA M. CRANE
DONNA P. LOPEZ
DEPUTY CITY CLERK
CITY CLERK
ABUTTERS FORM FOR SIGN/AWNING PERMIT
Date 06/02/2022
To Whom It May Concern:
Harvard Collection, LLC
Cambridge,
As Owner of Agent of
X
of the
approval
Massachusetts, I do hereby declare my disapproval
installment of:
Canopy over the sidewalk entrance:
Awnings over the windows:
X
Projecting sign:
of said property.
John Fitzpatrick, VP-Project Management
Date 06/02/2022
Signed:
Jamien
14, 16, 18, 20, & 22 Brattle Street, Cambridge, MA 02138
Address:
ABUTTERS:
Harvard Collection, LLC, c/o Regency Centers Corporation
PLEASE COMPLETE FORM WHETHER OR NOT YOU APPROVE OF THE REQUESTED
SIGN/AWNING AND RETURN IT TO THE APPLICANT WITHIN SEVEN (7) DAYS FOR INCLUSION
IN THE APPLICATION.
SIGN/AWNING APPLICANT:
PLEASE FILL IN DATE THAT FORM WAS DELIVERED TO ABUTTER (TOP RIGHT OF THIS
FORM)
CAMBRIDGE HISTORICAL COMMISSION
831 Massachusetts Avenue, 2nd FL., Cambridge, Massachusetts 02139
Telephone: [phone removed] Fax: [phone removed] TTY: [phone removed]
E-mail: histcomm@cambridgema.gov URL: http://www.cambridgema.gov/Historic
SLOGE HISTO
Bruce A. Irving, Chair, Susannah Barton Tobin, Vice Chair; Charles M. Sullivan, Executive Director
oseph V. Ferrara, Chandra Harrington, i
avin V. Kleespic, Pada A, Paris, Kyle Safeld, Ater a M. Solet, Yuting Zhang, Member:
COMMISSION
CERTIFICATE OF NONAPPLICABILITY
Property: 20 Brattle Street
Applicant: Harvard Collection, LLC
Attention: Joseph Correia, Boston Building Wraps
The Cambridge Historical Commission hereby certifies, pursuant to
Chapter 2.78, Article III of the Code of the City of Cambridge and
order establishing the Harvard Square Conservation District, that the
work described below does not involve any activity requiring issuance
of a Certificate of Appropriateness or Hardship:
Install a zoning compliant wall sign for the upper story tenants
and to indicate the entry address. Note that the application for
an internally-illuminated blade sign will be considered at the
November 3, 2022 meeting of the Historical Commission.
ISD #180606
All improvements shall be carried out as shown on the plans and
submitted by the applicant, except as modified above.
specifications
Approved plans and specifications are incorporated by reference into
this certificate.
This certificate is granted upon the condition that the work
authorized herein is commenced within six months after the date of
issuance. If the work authorized by this certificate is not commenced
within six months after the date of issuance or if such work is
suspended in significant part for a period of one year after the time
the work is commenced, such certificate shall expire and be of no
further effect; provided that, for cause, one or more extensions of
time for periods not exceeding
six months each may be allowed in
writing by the Chair.
Case Number: 4861
Date of Certificate: September 28, 2022
Attest: A true and correct copy of decision filed with the
office of the City Clerk and the Cambridge Historical Commission
on September 28, 2022.
By Charles M. Sullivan sl, Executive Director.
Twenty days have elapsed since the filing of this decision.
No appeal has been filed
- • Appeal has been filed
Date
, City Clerk
1912),
Engineers
1-2'
ELEVATION
EQ
1312 1
EXTENTS OF SIGN
www.tfmoran.com
Bedford, NH 03110
48 Constitution Drive
Fax #: [phone removed]
Phone #: [phone removed]
MIN. (6) 1/4 DIA. HILTI HLC
MIN. 1 1/4" EMBEDMENT
ANCHORS SPACED AS
SHOWN
AFTER INSTALL
BLADE SIGN CONNECTION
EX. BRICK
SECTION
8"
2'-10".
1'10 1/2".
PRESENT.
VOIDS ARE
SIGN FRAME
(BY OTHERS)
EXIST. METAL
NEW SIGN, SEE
BBW DRAWINGS
BLOCKING BEHIND
FACADE PROVIDE
7-0".
AT CONNECTIONS IF
1 1/2" = 1-0"
MIN. (3) 1/4" DIA. HILTI HLC OR
KWICK CON II ANCHORS PER
HORIZONTALLY AND
VERTICALLY
LETTER SPACED 6" MIN
TENSION LOAD OF 70 LBS.
AFTER INSTALL
TEST MIN. (2) ANCHORS TO A
LETTER SIGN CONNECTION
SECTION
1112" = 1-0
6/21/2022** TEL
TEL
VERB - BACKSTAGE
BOSTON BULDING WRAPS, INC.
NEW
SIGN CONNECTIONS AT BUILDING
LETTER
SIGN BY
OTHERS,
SEE BBW
S101
DRAWINGS
JOB TITLE BBW - The Abbot Battle Street
TFMoran Inc.
48 Constitution Drive
Cambridge, MA
SHEET NO.
Bedford, NH
JOB NO.
structura
DATE
6/21/22
CALCULATED BY ANB
[phone removed]
Engineers
DATE
6/21/22
CHECKED BY TEL
CS2018 Ver 2020.03.10
www.struware.com
STRUCTURAL CALCULATIONS
FOR
BBW - The Abbot Batttle Street
State:
MA
City:
Cambridge
ELEVATION
17
Cambridge, MA
International Building Code 2015
Pg Elevation
VRCII
VRCIII
VRCIV
mph
SS
0.216
S1
0.069
%g
ft
4
Frost Depth
40
psf
Pg@Elevation
JOB TITLE BBW - The Abbot Batttle Street
TFMoran Inc.
48 Constitution Drive
Cambridge, MA
Bedford, NH 03110
SHEET NO.
JOB NO.
DATE
6/21/22
CALCULATED BY ANB
[phone removed]
6/21/22
DATE
CHECKED BY TEL
ASCE 7- 10
Wind Loads:
128 mph
99.1 mph
Nominal Wind Speed
Risk Category
B
Exposure Category
Enclosure Classif.
Enclosed Building
Internal pressure
+/-0.18
Directionality (Kd)
0.85
0.701
Kh case 1
0.701
Kh case 2
Monoslope
Type of roof
VIZ)
Topographic Factor (Kzt)
Speed-up
Flat
Topography
80.0 ft
(H)
Hill Height
*(downwind)
100.0 ft
Half Hill Length (Lh)
xlupwind)
0.80
Actual H/Lh
=
H/2,
H
0.50
Use H/Lh
=
H/2
=
Modified Lh
160.0 ft
From top of crest: x=
50.0 ft
downwind
Bldg up/down wind?
ESCARPMENT
K, = 0.000
H/Lh= 0.50
V(z)
x/Lh = 0.31
K2 = 0.792
-Speed-up
z/Lh = 0.19
Kz = 1.000
V(z)
At Mean Roof Ht:
(downwind)
(upwind)
Kzt = (1+K,K2Kз)^2 = 1.00
H/2
H
H/2
2D RIDGE or 3D AXISYMMETRICAL HILL
Gust Effect Factor
Flexible structure if natural frequency < 1 Hz (T > 1 second).
If building h/B>4 then may be flexible and should be investigated.
30.0 ft
h=
h/B = 0.21
Rigid structure (low rise bldg)
B=
143.0 ft
30.0 ft
Iz (0.6h) =
G=
0.85 Using rigid structure default
Flexible or Dynamically Sensitive Structure
0.0 Hz
34 1y (n1) =
• Rigid structure
320 ft
30 ft
Damping ratio (B) =
0.25
la =
0.30
82.5
Vz=
3.4
90. 90 =
0.00
N, =
310.0 ft
Lz=
Rn =
0.000
0.83
Q=
h=
30.0 ft
0.000
28.282
12=
0.30
Rn =
n=
0.000
G=
28.282
RB =
0.83
n=
28.282
0.000
RL=
n=
0.000
9R =
0.000
R=
0.000
Gf =
Enclosure Classification
JOB TITLE BBW - The Abbot Battle Street
TFMoran Inc.
Cambridge, MA
48 Constitution Drive
JOB NO.
SHEET NO.
Bedford, NH 03110
DATE
[phone removed]
CALCULATED BY ANB
6/21/22
DATE
CHECKED BY TEL
6/21/22
A building that does not qualify as open or partially enclosed.
Test for Enclosed Building:
All walls are at least 80% open.
Test for Open Building:
Ao ≥ 0.8Ag
Test for Partially Enclosed Building: Predominately open on one side only
Test
Input
NO
500.0 sf
AOl
Ao ≥ 1.1 Aoi
YES
Ao > 4' or 0.01Ag
600.0 sf
Ag
Aoi / Agi ≤ 0.20
YES
1000.0 sf
Aoi
_Building is NOT
Partially Enclosed
10000.0 sf
Agil
Conditions to quality as Partially Enclosed Building. Must satisfy all of the following:
Ao ≥ 1.1Aoi
Ao> smaller of 4' or 0.01 Ag
Aoi / Agi ≤ 0.20
Ao = the total area of openings in a wall that receives positive external pressure.
Ag = the gross area of that wall in which Ao is identified.
Agi- the sum of the gross ou ace are i the uting elope ali an on reing a .,
Reduction Factor for large volume partially enclosed buildings (Ri) :
If the partially enclosed building contains a single room that is unpartitioned, the internal
pressure coefficient may be multiplied by the reduction factor Ri.
Total area of all wall & roof openings (Aog:
Unpartitioned internal volume (Vi) :
0 cf
1.00
Ri =
Altitude adjustment to constant 0.00256 (caution - see code) :
0.0765 Ibm/ft3
Average Air Density =
0.0 ft
Grd level above sea level =
Adj Constant = 0.00256
Constant =
0.00256
JOB TITLE BBW - The Abbot Batttle Street
TFMoran Inc.
48 Constitution Drive
Cambridge, MA
SHEET NO.
JOB NO.
Bedford, NH 03110
6/21/22
CALCULATED BY ANB
DATE
[phone removed]
CHECKED BY TEL
DATE
6/21/22
Ultimate Wind Pressures
ASCE 7-10
Wind Loads - Other Structures:
1.00
Wind Factor =
0.85 Ultimate Wind Speed =
128 mph
Exposure =
Gust Effect Factor (2) =
A. Solid Freestanding Walls & Solid Signs (& open signs with less than 30% open)
s/h=
0.33
Case A & B
C. =
1.84
B/s =
0.21
Dist to sign top (h)
12.0 ft
4.0 ft
32.1 As
F = qz G Cf As =
0.00
Height (s)
Lr/s =
Kz =
7.1 st
0.575
As =
Width (B)
0.8 ft
F =
qz=
227 Ibs
20.5 pst
Wall Return (Lr) =
0.85
Directionality (Kd)
CaseC
Percent of open area
Open reduction
to gross area
1.00
0.0%
factor =
Horiz dist from
cf
windward edge
39.2 AS
2.25
O to s
Case C reduction factors
1.50
26.1 As
Factor if s/h>0.8 =
1.00
s to 2s
Wall return factor
1.00
for Cf at 0 to s =
B. Open Signs & Lattice Frameworks (openings 30% or more of gross area
0.575
Kz =
15.0 ft
Height to centroid of Af (z)
20.5 pst
Base pressure (az) =
Width (zero if round)
19.2 AF
F = 92G C,A, =
Diameter (zero if rect)
D(qz) 5 =
10.0 s
Solid Area: A, =
Percent of open area
192lbs
F =
to gross area
1.1
Directionality (Kd)
C. Chimneys, Tanks, Rooftop Equipment (h>60") & Similar Structures
0.575
Kz =
Height to centroid of Af (z) 15.0 ft
21.7 psf
Square
Cross-Section
Base pressure (qz) =
h/D = 15.00
0.90
Directionality (Kd)
15.0 ft
Height (h)
1.0 ft
Width (D)
Type of Surface
Square (wind along diagona. 28
square (wind normal face)
30.7 Af
23.6 Af
F = 92 G G, A, =
F = qz G Cf Af =
10.0 sf
Af =
sf
A, =
307 Ibs
F=
F =
0 Ibs
D. Trussed Towers
0.575
15.0 ft
Kz =
Height to centroid of Af (z)
22.9 psf
Base pressure (qz) =
€ = 0.27
Tower Cross Section triangle
Diagonal wind factor =
flat
Member Shape
Round member factor =
0.95
1000
Directionality (Kd)
2.38
Triangular Cross Section
46.3 Af
F = 4, GG,A, =
Solid Area: A, =
10.0 sf
10.0
F=
463 Ibs
JOB TITLE BBW - The Abbot Battle Street
TFMoran Inc.
48 Constitution Drive
Cambridge, MA
Bedford, NH 03110
JOB NO.
SHEET NO.
6/21/22
DATE
[phone removed]
CALCULATED BY ANB
6/21/22
DATE
CHECKED BY TEL
Ultimate Wind Pressures
Vind Loads - Components & Cladding : h ≤ 60
ch (case 1)
30.0 ft
a =
12.0 ft
Base pressure (qh) = 25.0 psf
GCpi =
+/-0.18
3.0 ft
0.0 deg
User input
Surface Pressure (psf)
GCp +/- GCpi
Roof
20 sf
50 sf
500 sf
10 sf
100 sf
500 sf
50 sf
10 sf
50 st
100sf
-28.7
-27.T
-27.0
-27.0
-27.T
-1.08
-1.08
-32.0
-44.2
-32.0
-37.2
-37.2
285
-44.2
-32.0
-37.2
-32.0
-49.5
-37.2
1128
16.0
16.0
16.0
0.38
16.0
16.0
0.48
16.0
0.41
23.0
20.2
1.08
25.8
0.81
24.2
24.2
27.0
0.97
-41.7
-40.7
-27.5
-40.7
-42.5
-40.0
-40.7
-40.7
-42.5
-40.0
-27.5
-41.7
Ovatanang 20n82
1.89
Negative zone 3 = zone 2, since parapet >= 3ft.
verhang pressures in the table above assume an internal pressure coefficient (Gepi) of 0
erhang soffit pressure equals adj wall pressure (which includes internal pressure of 4.5 p
Parapet
User input
ap = 28.9 psf
50 sf
500 st
200 sil
20 sil
50 sfl
Solid Parapet Pressure
10 sil
51.8
50.0
Zone 2:
78.0
CASE A:
51.8
78.0
50.0
70.6
Zone 3:
-48.2
-39.0
-48.2
-51.9
42.7
-54.6
45.4
CASE B: Edge zones 2:
44.5
-52.8
Corner zones 3 :
-48.6
-52.8
-39.0
-62.4
-58.3
User input
GCp +/- GCpi
Walls
200 sf
5 st
500 sf
10 sf
100 sf
200 st
Area
-24.1
-292
-1.01
-1.17
-0,90
-0.96
-25.6
-36.0
-22.5
-1.03
-0.90
-1.12
20.2
21.8
0.87
-360
0.81
0.92
Positive one 48 5 1.04
Note: GCp reduced by 10% due to roof angle <= 10 deg.
JOB TITLE BBW - The Abbot Batttle Street
TFMoran Inc.
48 Constitution Drive
Cambridge, MA
JOB NO.
SHEET NO.
Bedford, NH 03110
DATE
6/21/22
CALCULATED BY ANB
[phone removed]
6/21/22
DATE
CHECKED BY TEL
Location of C&C Wind Pressure Zones - ASCE 7-10 & earlier
Za
2a
2a
aL
_2).
3
2)
4
WALL
Walls h ≤ 60'
Gable, Sawtooth and
Roofs w/ 0 ≤ 10°
Monoslope roofs
and all walls
Multispan Gable f ≤ 7 degrees &
& alt design h‹90'
3° < 0 ≤ 10°
Monoslope ≤ 3 degrees
h > 60'
h ≤ 60' & alt design h‹<90'
h ≤ 60' & alt design h‹90'
La
al
af
C
A
B
3
2X
(2)
3X
Multispan Gable &
Hip 7° < e ≤ 27°
Monoslope roofs
Gable 7° < e≤ 45°
10° < e ≤ 30°
h ≤ 60' & alt design h<90'
Sawtooth 10° < e ≤ 45°
h ≤ 60' & alt design h<90°
12
2
3/
b
b
b
W3
W1
W2
W1
W2
W
W
Stepped roofs 0 ≤ 3°
h ≤ 60' & alt design h<90'
JOB TITLE BBW - The Abbot Battle Street
TFMoran Inc.
48 Constitution Drive
Cambridge, MA
JOB NO.
SHEET NO.
Bedford, NH 03110
DATE
CALCULATED BY ANB
6/21/22
[phone removed]
DATE
6/21/22
CHECKED BY TEL
Location of C&C Wind Pressure Zones - ASCE 7-16
2a
La
2a
0.6h, 0.6h1
H0.2h
3
13
2
+
WALL
13
Walls h ≤ 60'
Gable, Sawtooth and
Roofs w/ 9 ≤ 10°
Multispan Gable 0 ≤ 7 degrees &
Monoslope roofs
& alt design h<90°
and all walls
h > 60'
3° < e ≤ 10°
Monoslope ≤ 3 degrees
h ≤ 60' & alt design h<90'
h ≤ 60' & alt design h<90'
D
B
A
C
al
Ô
Multispan Gable &
Hip 7° < 0 ≤ 27°
Monoslope roofs
10° < 0 ≤ 30°
Gable 7° < 0 ≤ 45°
2)
h ≤ 60' & alt design h<90'
Sawtooth 10° < 0 ≤ 45°
h ≤ 60' & alt design h<90'
310/
070
2<3
b
b
.b.
W1
W3
W2
W2
W1
W
W
Stepped roofs 0 ≤ 3°
1 ≤ 60' & alt design h<90
JOB TITLE BBW - The Abbot Batttle Street
TFMoran Inc.
Cambridge, MA
48 Constitution Drive
SHEET NO.
JOB NO.
Bedford, NH 03110
6/21/22
DATE
CALCULATED BY ANB
[phone removed]
6/21/22
DATE
CHECKED BY TEL
Strength Level Forces
IBC 2015
Seismic Loads:
Importance Cactor ():
Site Class : D
21.60 %g
Ss (0.2 sec) =
S1 (1.0 sec) =
6.90 %g
esign Category
SDS =
0.230
Sms =
0.346
1.600
Fa =
esign Category
0.110
Sm1 =
0.166
2.400
S01 =
Fv =
Seismic Design Category =
1.00
Redundancy Coefficient p =
3
Number of Stories
Structure Type: All other building system:
Horizontal Struct Irregularities:No plan Irregularity
Vertical Structural Irregularities:No vertical Irregularity
Flexible Diaphragms: Yes
Seismic residing system: Stuctural stel yatoms no special detaied tor solismic resistance
System Structural Height Limit: Height not limited
Actual Structural Height (hn) = 30.0 ft
DESIGN COEFFICIENTS AND FACTORS
3
Response Modification Coeficient (R) =
2.5
ver-Strength Factor (20)
eflection Amplification Factor (ca)
3
0.230
SDs =
0.110
Sp1 =
Eh +/-Ev = p GE +/- 0.2Sps D
Seismic Load Effect (E) =
= Qe +/- 0.046D
O = harional selsmic foro
= 2.5Qe +/- 0.046D
Special Seismic Load Effect (Em) : Emh +/- Ev = 20 Q +/- 0.2SDs D
PERMITTED ANALYTICAL PROCEDURES
- Use Equivalent Lateral Force Analysis
Simplified Analysis
Equivalent Lateral-Force Analysis
- Permittec
Cu = 1.68
0.020
Building period coef. (C) =
0.256 sec x= 0.75
Approx fundamental period (Ta) :
Tmax = CuTa = 0.431
Chn =
sec
Use T = 0.256
User calculated fundamental period (T) =
6
ASCE map =
Long Period Transition Period (TL) =
0.077
Seismic response coef. (Cs) =
need not exceed Cs =
0.144
Sd1 I/RT =
0.010
0.044Sdsl =
0.077
Design Base Shear V = 0.077W
Model & Seismic Response Analysis
- Permitted (see code for procedure)
ALLOWABLE STORY DRIFT
All other structures
Structure Type:
Allowable story drift Aa = 0.020hsx
where hsx is the story height below level x
JOB TITLE BBW - The Abbot Batttle Street
TFMoran Inc.
48 Constitution Drive
Cambridge, MA
Bedford, NH 03110
JOB NO.
SHEET NO.
DATE 6/21/22
CALCULATED BY ANB
[phone removed]
CHECKED BY TEL
DATE 6/21/22
Strength Level Forces
Seismic Design Category (SDC) = B
Seismic Loads - cont. :
le = 1.00
Sds = 0.230
CONNECTIONS
Force to connect smaller portions of structure to remainder of structure
Fp = 0.133Sdsw, =
0.031 Wp
or Fp = 0.05Wp =
Wp = weight of smaller portion
0.05 Wp
Use Fp = 0.05 Wp
Beam, girder or truss connection for resisting horizontal force parallel to member
Fp = no less than 0.05 times dead plus live load vertical reaction
Anchorage of Structural Walls to elements providing lateral support
Flexible diaphragm span Lf =
Fp = not less than 0.2KaleWp
Enter f to calculate Fp for flexible diaphragm
ka= 1 Fp =
Fp =0.4SdskaleWp = 0.092 Wp, but not less than 0.2Wp (rigid diaphragm)
but Fp shall not be less than 5 psf
MEMBER DESIGN
Bearing Walls and Shear Walls (out of plane force)
0.092 ww
Fp = 0.4SdsleWw =
Use Fp =
0.10 Ww
0.10 WW
but not less than
Diaphragms
Fp = 0.2|SdsWp + Vpx =
0.046 Wp + Vpx
Seismic Design Category B & Ip=1.0, therefore
ARCHITECTURAL COMPONENTS SEISMIC COEFFICIENTS
only required for parapets supported by bearing or shear walls
Architectural Component: Signs and Billboards
Importance Factor (lp): 1.0
50.0 feet
2.5
h=
Component Amplitication Factor (ap) :
0.24
z/h =
12.0 feet
Z=
3
homp Kesponse Moditication Factor (K) =
0.114 Wp
Fp = 0.4a,SdslpWp(1+2z/h)/Rp =
not greater than Fp = 1.6SdslpWp =
0.369 Wp
but not less than Fp = 0.3SdslpWp =
0.114 Wp
0.069 Wp
use Fp =
Seismic Design Category B, therefore
MECH AND ELEC COMPONENTS SEISMIC COEFFICIENTS
not required
Mech or Electrical Component: Wet-side HVAC, boilers, furnaces, atmospheric tanks and bins, chillers, water heaters, etc
plus other mechanical components constructed of high-deformability materials.
Importance Factor (lp) : 1.0
1
h=
30.0 feet
Component Amplitication Factor (ap) =
50.0 feet
2.5
Z=
z/h = 1.00
Comp Kesponse Moditication Factor (K) =
Fp = 0.4a,SdslpWp(1+2z/h)/Rp =
0.111 Wp
not greater had p=13s/pW1=
0.369 Wp
use Fp =
0.111 Wp
but not less than Fp = 0.3SdslpWp =
0.069 Wp
Date: 03-23-2022
Calculated By: ANB
Project: BBW -The Abbot
Date: 03-23-2022
Checked By: TEL
Backer Panel Connection Design
Note
Value
Equation
Notation (Units)
Sign Information
Height
H (ft)
2.75
Width
5.33
W(ft)
t (ft)
Thickness
0.16667
14.66
Elevation Area
A (ft^ 2)
0.46
PA (ft^2)
Projected Area
0
x (ft)
Wall Offset
5
y (psf)
Self-Weight
Ls (ft)
Shaft Length
0
HSS 2x2x1/4
ws (plf)
Shaft Self-Weight
Connection Information
0.25
Db (in)
Size of Bolts
nb
6
Number of Bolts
16
sh (in)
Horiz. Spacing
16
Vert. Spacing
sv (in)
Loads
Pd (Ib)
Y*A
Dead Load
73.2875
Wind
StruWare C&C
wws (psf)
36
Suction
StruWare C&C
wwn (psf)
36
Normal
Struware other wind
Case A & B
32.1
wwnAB (psf)
use C&C loads
Load 1
wwnC1 (psf)
39.9
wwnC2 (psf)
26.6
Load 2
Struware Arch.
0.114*(y*A+ws*Ls)
E (Ibs)
11.7
Seismic
Components Seismic
Coefficients
Design Sign Connection
1. Resultant Forces Due to Vertical Load
Pd+ws*Ls
Vv (Ib)
Shear
73.2875
Vv/nb
12.2146
Vvb (Ib)
Shear Per Bolt
Pd*t/2
6.11
Mv (Ib-ft)
Moment
Tv (Ib)
4.58
Mv/(sv/12)
Tension
Tv/(nb/2)
Tvb (Ib)
1.52682
Tension Per Bolt
2. Resultant Forces Due to Suction Load
wWs*H*W
Force
P (Ib)
527.67
P/nb
87.945
Tsb (Ib)
Tension Per Bolt
Structural
Engineers
Date: 03-23-2022
Calculated By: ANB
Project: BBW -The Abbot
Date: 03-23-2022
Checked By: TEL
Note
Equation
Notation (Units) Value
3. Resultant Forces Due to Normal Wind Load
Wind Normal To
Case A
Sign Centroid
wwnAB*A
14.7125
PA (Ibs)
Load
Load Distance To
t/2+x
x1 (ft)
0.08333
Support
PA/nb
VnAb (Ib)
Shear Per Bolt
2.45
PA*x1
1.23
Moment
MnA (Ib-ft)
MnA/sh
Tension
ThA (Ib)
0.08
0.02554
Tension Per Bolt
TnAb (Ib)
TnA/(nb/2)
Load Offset 20%
Case B
From Centroid
wwnAB*A
Load
14.7125
PB (Ibs)
Load Distance To
0.2*D+D/2+x
0.11667
x1 (ft)
Support
PB/nb
VnBb (Ib)
Shear Per Bolt
2.45
PB*x1
Moment
1.72
MnB (Ib-ft)
MnB/sh
0.11
ThB (Ib)
Tension
TnB/(nb/2)
0.04
Tension Per Bolt
TnBb (Ib)
C&C
wws*A
33
PB (Ibs)
Load
Load Distance To
0.08333
t/2+x
x1 (ft)
Support
PB/nb
VnBb (Ib)
Shear Per Bolt
5.50
PB*x1
Moment
MnB (Ib-ft)
2.75
MnB/sh
TnB (Ib)
TnB/(nb/2)
ThBb (Ib)
Tension Per Bolt
4. Determine Connection Wind Design Loads
max(Vv,PA,PB)
73.2875
Total Shear
V (Ibs)
max(Vvb, VnAb, VnBb)
12.21
Bolt Shear
max(TnAb,TnBb)+Tvb+Tsb
89.53
Bolt Tension
Tb (Ibs)
Note
Notation (Units)
Value
Equation
5. Check Seismic
E<V
Wind Governs
Check
6. Check Anchorage
1/4" hilti quick con Il 1" embed
Selected
205
Ta (Ib)
Allowable Tension
415
Allowable Shear
Va (Ib)
Tb<Ta
Ok
Tension Check
Vb<Va
Ok
Shear Check
Structural
Engineers
Date: 03-23-2022
Project: BBW -The Abbot
Calculated By: ANB
Date: 03-23-2022
Checked By: TEL
Letter Sign Connection Design
Note
Equation
Value
Notation (Units)
Sign Information
H (ft)
1.5
Height
W(ft)
Width
1.5
t (ft)
Thickness
0.16667
A (ft^2)
2.25
Elevation Area
0.25
PA (ft^2)
Projected Area
0
Wall Offset
x (ft)
5
y (psf)
Self-Weight
0
Ls (ft)
Shaft Length
HSS 2x2x1/4
ws (plf)
Shaft Self-Weight
Connection Information
0.25
Db (in)
Size of Bolts
nb
2
Number of Bolts
sh (in)
0.5
Horiz. Spacing
0.5
sv (in)
Vert. Spacing
Loads
Pd (Ib)
Y*A
Dead Load
11.25
Wind
StruWare C&C
36
Suction
wws (psf)
StruWare C&C
36
wwn (psf)
Normal
Struware other wind
32.1
wwnAB (psf)
Case A & B
use C&C loads
39.9
Load 1
wwnC1 (psf)
wwnC2 (psf)
26.6
Load 2
Struware Arch.
0.114*(y*A+ws*Ls)
1.8
E (Ibs)
Seismic
Components Seismic
Coefficients
Design Sign Connection
1. Resultant Forces Due to Vertical Load
Pd+ws* Ls
11.25
Vv (Ib)
Shear
Vv/nb
5.625
Shear Per Bolt
Vvb (Ib)
Pd*t/2
0.94
Mv (Ib-ft)
Moment
Mv/(sv/12)
Tension
Tv (Ib)
22.50
Tv/(nb/2)
Tension Per Bolt
Tvb (Ib)
22.5
2. Resultant Forces Due to Suction Load
wws*H*W
81
Force
P (Ib)
P/nb
40.5
Tension Per Bolt
Tsb (Ib)
Structural
Engineers
Date: 03-23-2022
Calculated By: ANB
Project: BBW -The Abbot
Date: 03-23-2022
Checked By: TEL
Note
Equation
Notation (Units) Value
3. Resultant Forces Due to Normal Wind Load
Wind Normal To
Case A
Sign Centroid
wwnAB*A
PA (Ibs)
8.025
Load
Load Distance To
0.08333
x1 (ft)
t/2+x
Support
4.01
VnAb (Ib)
Shear Per Bolt
PA/nb
0.67
PA*x1
Moment
MnA (Ib-ft)
MnA/sh
1.34
TnA (Ib)
Tension
1.3375
TnAb (Ib)
Tension Per Bolt
TnA/(nb/2)
Load Offset 20%
Case B
From Centroid
wwnAB*A
Load
8.025
PB (Ibs)
Load Distance To
0.2*D+D/2+x
0.11667
x1 (ft)
Support
PB/nb
Shear Per Bolt
VnBb (Ib)
4.01
PB*x1
Moment
0.94
MnB (Ib-ft)
MnB/sh
TnB (Ib)
1.87
Tension
TnB/(nb/2)
1.87
TnBb (Ib)
Tension Per Bolt
C&C
wws*A
18
Load
PB (Ibs)
Load Distance To
t/2+x
0.08333
x1 (ft)
Support
PB/nb
9.00
Shear Per Bolt
VnBb (Ib)
PB*x1
Moment
MnB (Ib-ft)
1.50
MnB/sh
Tension
TnB (Ib)
3.00
TnB/(nb/2)
3.00
TnBb (Ib)
Tension Per Bolt
4. Determine Connection Wind Design Loads
18
V (Ibs)
max(Vv,PA,PB)
Total Shear
9.00
max(Vvb, VnAb, VnBb)
Vb (Ibs)
Bolt Shear
max(TnAb,TnBb)+Tvb+Tsb
66.00
Bolt Tension
Tb (Ibs)
Note
Value
Equation
Notation (Units)
5. Check Seismic
E<V
Wind Governs
Check
6. Check Anchorage
#8 HILTI SELF TAPPING SCREW
Selected
Allowable Tension
225
Ta (lIb)
525
Allowable Shear
Va (Ib)
Ok
Tb<Ta
Tension Check
Vb<Va
Ok
Shear Check
TAN.
Structural
Engineers
Date: 03-23-2022
Project: BBW -The Abbot
Calculated By: ANB
Date: 03-23-2022
Checked By: TEL
Triangle Sign Connection Design
Note
Equation
Value
Notation (Units)
Sign Information
7
Height
H (ft)
Width
W(ft)
1.75
t (ft)
Thickness
1.875
Elevation Area
A (ft^2)
12.25
13.13
PA (ft^2)
Projected Area
0
x (ft)
Wall Offset
5
y (psf)
Self-Weight
Ls (ft)
Shaft Length
0
HSS 2x2x1/4
Shaft Self-Weight
ws (plf)
Connection Information
0.75
Db (in)
Size of Bolts
nb
6
Number of Bolts
1.167
sh (in)
Horiz. Spacing
34
sv (in)
Vert. Spacing
Loads
y*A
Pd (Ib)
Dead Load
61.25
Wind
StruWare C&C
36
Suction
wws (psf)
StruWare C&C
36
wwn (psf)
Normal
Struware other wind
32.1
Case A & B
wwnAB (psf)
use C&C loads
39.9
wwnC1 (psf)
Load 1
26.6
Load 2
wwnC2 (psf)
Struware Arch.
0.114*(y*A+ws*Ls)
9.7
Seismic
E (Ibs)
Components Seismic
Coefficients
Design Sign Connection
1. Resultant Forces Due to Vertical Load
Pd+ws* Ls
Vv (Ib)
Shear
61.25
Vv/nb
Shear Per Bolt
Vvb (Ib)
10.2083
Pd*t/2
Mv (Ib-ft)
57.42
Moment
20.27
Tv (Ib)
Tension
Mv/(sv/12)
Tv/(nb/2)
Tvb (Ib)
Tension Per Bolt
6.75551
2. Resultant Forces Due to Suction Load
wws*H*W
441
Force
P (Ib)
P/nb
Tension Per Bolt
Tsb (Ib)
73.5
Structural
Engineers
Project: BBW -The Abbot
Calculated By: ANB
Date: 03-23-2022
Date: 03-23-2022
Checked By: TEL
Note
Equation
Notation (Units) Value
3. Resultant Forces Due to Normal Wind Load
Wind Normal To
Case A
Sign Centroid
wwnAB*A
421.313
Load
PA (Ibs)
Load Distance To
0.9375
t/2+x
x1 (ft)
Support
PA/nb
VnAb (Ib)
Shear Per Bolt
70.22
PA*x1
394.98
Moment
MnA (Ib-ft)
338.46
MnA/sh
Tension
TnA (Ib)
112.819
Tension Per Bolt
TnAb (Ib)
TnA/(nb/2)
Load Offset 20%
Case B
From Centroid
421.313
wwnAB*A
Load
PB (Ibs)
Load Distance To
0.2*D+D/2+x
x1 (ft)
1.3125
Support
PB/nb
VnBb (Ib)
Shear Per Bolt
70.22
PB*x1
MnB (Ib-ft)
Moment
552.97
MnB/sh
TnB (Ib)
473.84
Tension
TnB/(nb/2)
TnBb (Ib)
Tension Per Bolt
157.95
C&C
945
wws*A
Load
PB (Ibs)
Load Distance To
t/2+x
0.9375
x1 (ft)
Support
PB/nb
157.50
VnBb (Ib)
Shear Per Bolt
PB*x1
885.94
Moment
MnB (Ib-ft)
MnB/sh
ThB (Ib)
Tension
759.16
TnB/(nb/2)
253.05
Tension Per Bolt
TnBb (Ib)
4. Determine Connection Wind Design Loads
V (Ibs)
945
Total Shear
max(Vv,PA,PB)
157.50
max(Vvb, VnAb, VnBb)
Bolt Shear
Vb (Ibs)
max(TnAb, TnBb)+Tvb+Tsb
Bolt Tension
333.31
Tb (Ibs)
Note
Value
Equation
Notation (Units)
5. Check Seismic
E<V
Wind Governs
Check
6. Check Anchorage
3/8" hilti quick con Il 1" embed
Selected
Allowable Tension
Ta (Ib)
350
305
Va (Ib)
Allowable Shear
Tb<Ta
Ok
Tension Check
Vb<Va
Shear Check
OK
TEN.
Structural
Engineers
HILTI
The following excerpt are pages from the North American
Product Technical Guide, Volume 2: Anchor Fastening, Edition
21.
Please refer to the publication in its entirety for complete details
on this product including data development, product
specifications, general suitability, installation, corrosion and
spacing and edge distance guidelines.
US&CA: https://submittals.us.hilti.com/PTGVol2/
To consult directly with a team member regarding our anchor
fastening products, contact Hilti's team of technical support
specialists between the hours of 7:00am - 6:00pm CST.
US: [phone removed] or [email removed]
CA: [phone removed], ext. 6 or [email removed]
Hilti, Inc.
7250 Dallas Parkway, Suite 1000
Plano, TX 75024
[phone removed]
www.hilti.com
HILTI
3.3.19 HLC SLEEVE ANCHOR
PRODUCT DESCRIPTION
HLC Sleeve anchors
Features and Benefits
Anchor System
• Anchor suitable for through-hole installation
Bolt head - HLC-H
• Anchor and masonry bit are the same
diameter
Hex Nut - HLC-HX
• Good selection of anchor diameters,
lengths and head configurations offer
versatility
Flat Phillips Head - HLC-FPH
• Load data for concrete, hollow masonry,
solid masonry and brick
Tie-Wire Head - HLC-T
• Extrusions on sleeve prevent the anchor
from spinning in hole during installation
or dropping out of overhead hole prior to
applying installation torque.
Acorn Nut - HLC-AC
Round Head Slotted - HLC-RS
Rod Coupling - HLC-RC
Grout-filled
Uncracked
Hollow brick
Ungrouted
concrete
concrete masonry
concrete masonry
MATERIAL SPECIFICATIONS
Carbon steel epansion sleeves and spacer sleeves are manufactured from cold rolled steel.
Carbon steel anchors are zinc plated in accordance with ASTM B633, SC 1, TYPE III.
Stainless steel anchor components are manufactured from AISI Type 304 stainless steel.
Table 1 - Hilti HLS Sleeve anchor specification table
Nominal anchor diameter
3/4
5/8
1/2
5/16
1/4
Setting information
Symbol
3/8
5/8-11
in.
UNC
3/8-16
1/4-20
Thread size
5/16-18
1/2-13
3/16-24
in.
Nominal bit diameter
1/2
5/16
1/4
3/8
ChIL
1
1
in.
1-1/4
1-1/2
Minimum nominal
hnom
embedment
(51)
(51)
(25)
(32)
(25)
(38)
(mm)
2-5/8
2-5/8
1-3/4
in.
2-1/8
1-3/8
1-3/8
Minimum hole depth
h.
(67)
(35)
(35)
(mm)
(45)
(67)
(54)
12
ft-lb
35
18
Tinst®
:
:
(16)
(47)
(Nm)
(24)
Installation torque
5
2
90
60
ft-lb
15
10
Tins?
(122)
(14)
(20)
(Nm)
(81)
(3)
1 HLC-H Bolt Head model.
2 HLC-HX, HLC-FPH, HLC-AC, HLC-RS and HLC-RC models.
Anchor Fastening Technical Guide Edition 21 | 3.0 ANCHORING SYSTEMS | 3.3.19 HLC SLEEVE ANCHOR
486
Hilti, Inc. [phone removed] | en español [phone removed] | www.hilti.com | Hilti (Canada) Corporation | www.hilti.ca | [phone removed]
Anchor Fastening Technical Guide, Edition 21
Table 2 - Carbon steel sleeve anchor allowable loads in concrete
f'. = 6,000 psi
/ c= 4,000 psi
f'. = 2,000 psi
Nominal
Nominal
Bolt
Tension
Shear 2
Shear 2
Tension
Shear 2
Tension
embedment
anchor
diameter
Ib
Ib
lb
Ib
(kN)
(kN)
Ib
(KN)
in.
diameter
(mm)
Ib
(kN)
(kN)
in.
(KN)
305
250
(1.1)
(1.4)
305
250
(1.1)
305(1.4)
(1.4)
3/16
225(1.0)
(25)
1/4
500
560
560
450
560
(2.5)
350
(2.2)
25)
1
(2.0)
(2.5)
(1.5)
(25)
5/16
1/4
890
700
(3.9)
870
870
(4.4)
(3.1)
450
565
(2.0)
(32)
(3.9)
(2.5)
5/16
1-1/4
3/8
1,100
1,325 (5.9)
925
(4.9)
(5.9)
(5.6)
(4.1)
675
1,250
1,325
1-1/2
(38)
(3.0)
3/8
1/2
1,950
1,500
1,750
2,295 (10.2)
2,295 (10.2)
(6.7)
(8.7)
(7.8)
2
1,035 (4.6)
(51)
5/8
12
1,950
1,500
1,750
1,125
3,000 (13.3)
(7.8)
(8.7)
(51)
(6.7)
2
3,010 (13.4)
(5.0)
5/8
3/4
Based on a safety factor of 4.0.
2
For 1/4- and 3/8-in, flat phillips and round head anchors, shear values should be reduced by 57% due to the potential of the shear acting through the hollow portion of the head.
Table 3 - Stainless steel sleeve anchor allowable loads'
Hollow C-90 concrete block?
= 4,000 psi
f'. = 2,000 psi
Nominal
Nominal
Shear
Shear
Tension
Shear
Tension
Tension
embedment
anchor
lb
Ib
lb
Ib
(KN)
(KN)
(kN)
(kN)
(kN)
diameter
in.
(mm)
(KN)
300
400
450
235
(1.8)
200
450
(0.9)
(2.0)
1-1/8
(2.0)
(1.0)
(29)
(1.3)
1/4
310
410
600
675
(1.5)
335
(3.0)
(1.4)
(3.0)
(32)
(1.8)
(2.7)
5/16
1-1/4
675
600
450
890
1,000
(4.4)
(4.0)
1,000
470
(4.4)
(2.1)
(2.7)
(38)
(2.0)
1-1/2
3/8
Based on using a safety factor of 4.
Table 5 - Carbon steel sleeve anchor allowable loads
Table 4 - Carbon steel sleeve anchor allowable loads
in hollow concrete block 2,3,4
in grout-filled block 1,2,3,4,5,6,7
Nominal
Nominal
Nominal
Edge
Nominal
Shear
Anchor
Tension
embedment
Tension
distance
Shear
embedment
anchor
(kN)
Ib
in.
(kN)
Ib
(mm)
in. mm)
Diameter
diameter
Ib (kN)
in. (mm)
(kN)
305
(1.4)
(1.5)
350
1/4
(25)
4(101)
305(1.4)
1
290 (1.3)
(25)
1/4
560
(25)
375
5/16
(2.5)
(1.7)
≥ 12 (305)
435
800
(3.5)
(1.9)
1-1/4 (32)
3/8
4 (101)
500(2.2)
1
385 (1.7)
(25)
5/16
565
(2.5)
(5.0)
1/2
1,125
1-1/2
38)
≥ 12(305)
Based on using a safety factor of 4.
4 (101)
2 ASTM Specification C90, Type II.
725 (3.2)
435(1.9)
1-1/4 (32)
3/8
≥ 12(305)
3 Installation in the mortar joints is outside the scope of the published data.
Anchors are limited to one per unit cell with a minimum edge distance of 12 inches.
865(3.8)
4 (101)
605
1-1/2 (38)
(2.7)
1/2
1,145 (5.1)
≥ 12(305)
1,050 (4.7)
4 (101)
2
710 (3.2)
(51)
5/8
1,815 (8.1)
≥ 12 (305)
4
1,050 (4.7)
(101)
2
Table 6 - Carbon steel sleeve anchor allowable loads
(51)
3/4
840 (3.7) 1,970 (8.8)
≥ 12 (305)
in clay brick12,3,4
1 Values are for lightweight, medium-weight or normal-weight
concrete masonry units conforming to ASTM C90 with 2,000 psi grout conforming to
Nominal
Nominal
ASTM C474.
Shear
Tension
embedment
Anchor
2 Embedment depth is measured from the outside face of the
(kN)
in.
(KN)
(mm)
concrete masonry unit.
Diameter
3 Values are for anchors located in the grouted cell, bed joint, cross web or any combina-
305
350
(1.4)
(1.5)
(25)
1/4
tion of the above.
1
4 For anchors installed in the T joint or head joint reduce tension
530
(2.3)
345
(1.5)
5/16
(25)
values by 20%.
850
(3.8)
(1.7)
375
3/8
1-1/4
(32)
5 Values for edge distances between 4 inches and 12 inches may be calculated by linear inter-
(5.5)
435
polation.
1,230
(38)
(1.9)
1/2
1-1/2
6 Anchors are limited to one per unit cell.
7 Based on using a safety factor of 4.
2 Bus to orde strength vartations enc
Due to wide strength variations encountered in masonry, these values should be
3.3.19
3 Installation in the mortar joints is outside the scope of the published data.
Minimum anchor spacing shall be two (2) complete bricks in any direction. Minimu
ge distance shall be the lesser of two (2) complete bricks or 16 inches in any directi
487
nchor Fastening Technical Guide Edition 21 | 3.0 ANCHORING SYSTEMS | 3.3.19 HLC SLEEVE ANCHOP
tilti, Inc. [phone removed] | en español [phone removed] | www.hilt.com | Hilti (Canada) Corporation | www.hilti.ca | 1-800-363-445
HITI
INSTALLATION INSTRUCTIONS
Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded
online at www.hilti.com. Because of the possibility of changes, always verify that downloaded FU are current when used.
Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services
for applications and conditions not addressed in the IFU.
ORDERING INFORMATION'
Round head slotted (RS)
Nominal
inimu
nbedme
Bolt thread
bit diameter
Description
Qty / box
HLC-RS 1/4 x 1-1/4
100
1/4
3/16-24
100
HLC-RS 1/4 x 2
1/4
3/16-24
100
1/4
3
HLC-RS 1/4 x 4
3/16-24
A
Bolt head (H)
Minimum
Fastens
Nominal
embedment
bit diameter
Bolt thread
Qty / box
materials up to
Description
1
100
5/16
1/4-20
5/8
HLC-H 5/16 x 1-5/8
1-5/8
100
1/4-20
1
5/16
HLC-H 5/16 x 2-5/8
1-1/4
5/8
5/16-18
HLC-H 3/8 × 1-7/8
3/8
50
HLC-H 3/8 x 3
1-1/4
5/16-18
1-3/4
3/8
50
1/2
3/4
3/8-16
1-1/2
HLC-H 1/2 x 2-1/4
1-1/2
25
HLC-H 1/2 x 3
3/8-16
1/2
1-1/2
25
1-1/2
2-1/2
HLC-H 1/2 x 4
1/2
3/8-16
A
Flat phillips head (FPH)
Fastens
Minimum
Nominal
Bolt thread
embedmen
bit diameter
Qty / box
materials up to
Description
100
HLC-FPH 1/4 x 1-3/8
3/8
3/16-24
1/4
100
1
3/16-24
1/4
HLC-FPH 1/4 x 2
100
1
2
3/16-24
1/4
HLC-FPH 1/4 x 3
100
3
1
1/4
3/16-24
HLC-FPH 1/4 x 4
1-1/4
50
1-1/2
3/8
5/16-18
HLC-FPH 3/8 x 2-7/8
50
1-1/4
- 2-3/4
5/16-18
3/8
HLC-FPH 3/8 x 4
1-1/4
3-3/4
25
3/8
5/16-18
25
4-3/4
1-1/4
5/16-18
3/8
HLC-FPH 3/8 x 6
1 All dimensions in inches
Definition of nomenclature
utside diameter of sleeve, see tables
for threaded bolt diameter
HLG-AC 774 X 1-3/8
The overall length from bottom
Nut configuration
of washer to end of sleeve
Anchor Fastening Technical Guide Edition 21 | 3.0 ANCHORING SYSTEMS | 3.3.19 HLC SLEEVE ANCHO
488
Hilti, Inc. [phone removed] | en español [phone removed] | www.hilti.com | Hilti (Canada) Corporation | www.hilti.ca | 1-800-363-445
Anchor Fastening Technical Guide, Edition 21
A
Hex nut (HX)
Fastens
Minimum
materials up to
Bolt thread
embedment
Description
1
1/2
1/4-20
HLC-HX 5/16 x 1-5/8
1/4-20
1 -1/2
1
HLC-HX 5/16 x 2-5/8
5/8
5/16-18
1-1/4
HLC-HX 3/8 x 1-7/8
HLC-HX 3/8 x 3
1-3/4
5/16-18
1-1/4
3/8-16
HLC-HX 1/2 x 2-1/4
3/4
1-1/2
1-1/2
3/8-16
1-1/2
HLC-HX 1/2 x 3
1-1/2
2-1/2
3/8-16
HLC-HX 1/2 x4
3/8-16
1-1/2
4-1/2
HLC-HX 1/2 x 6
1/4
1/2-13
2
HLC-HX 5/8 x 2-1/4
1/2-13
2-1/4
2
HLC-HX 5/8 x 4-1/4
4
2
1/2-13
HLC-HX 5/8 x 6
2
5/8-11
1/2
HLC-HX 3/4 x 2-1/2
5/8-11
2
1-3/4
HLC-HX 3/4 x 4-1/4
2
5/8-11
3-3/4
HLC-HX 3/4 x 6-1/4
3/4
A
Acorn head (AC)
Fastens
Minimum
Nominal
embedment
materials up to
bit diameter
Description
Bolt thread
Qty / box
100
3/16-24
3/8
1/4
HLC-AC 1/4 x 1-3/8
100
3/16-24
1
1-1/4
1/4
HLC-AC 1/4 x 2-1/4
-A-
fiMtninuto
304SS sleeve anchors
Fastens
Nominal
Minimum
materials up to
Bolt thread
bit diameter
embedment
Description
Qty / box
1-1/8
100
3/16-24
1-1/8
1/4
HLC-HX 304SS 1/4 x 2-1/4
HLC-HX 304SS 5/16 x 1-1/2
1/4
1/4-20
100
5/16
1-1/4
100
1/4-20
5/16
1-1/4
HLC-HX 304SS 5/16 x 2-1/2
1-1/4
50
5/16-18
3/8
HLC-HX 304SS 3/8 x 1-7/8
3/8
1-1/2
50
HLC-HX 304SS 3/8 x 3
5/16-18
1-1/2
3/8
1-1/2
Rod coupling (RC)
Faster
Nomina
it diamete
Bolt thread
naterials up t
Qty / box
Description
Minument
50
5/16 x 3/8
1-1/4
5/16-18
3/8
HLC-RC 3/8 x 1-7/8
25
3/8 x1/2
1-1/2
1/2
3/8-16
HLC-RC 1/2 x 2-1/4
-A→
Tie-wire head (T)
3.3.19
Minimum
Nominal
Qty /box
embedment
bit diameter
Bolt thread
Description
50
1-3/8
3/16-24
1/4"
HLC-T 1/4 x 1-3/8
1 All dimensions in inches
Definition of nomenclature
Outside diameter of sleeve, see tablesfor threaded bolt diameter
HLC-AC 1/4 X 1-3/8
The overall length from bottom of washer to end of sleeve
Nut configuration
chor Fastening Technical Guide Edition 21 | 3.0 ANCHORING SYSTEMS | 3.3.19 HLC SLEEVE ANCHO
489
Iti. Inc. [phone removed] | en español [phone removed] | www.hilti.com | Hilti (Canada) Corporation | www.hilti.ca | 1-800-363-44
HILT
KWIK-CON II+
CONCRETE AND
MASONRY
SCREW
HILT!
KWIK-CON II+ CONCRETE AND MASONRY SCREW
PRODUCT DESCRIPTION
KWIK-CONN II+ concrete and masonry screw anchors
Anchor System
Features and Benefits
• Improved silver KWIK Cote finish that
exceeds 1000 hours of protection from red
rust in ASTM B117
• Salt spray testing
• More durable than zinc plating
• Zinc electroplating and passivation with
chromate require toxic chemicals. The
KWIK Cote zinc rich organic finish is easy
on the environment
KWIK-CON Il+ fastener
• Zinc electroplating and passivation with
chromate require toxic chemicals. The
KWIK Cote zinc rich organic finish is easy
on the environment
• Applicable specific carbide tipped bits
optimize performance in concrete or
masonry
• Torx Hex washer head for fast secure
driving
• Torx or Phillips flat head for countersunk
KWIK-CON Il+ drive tool, and
a Hilti matched tolerance
carbide-tipped drill bit.
Uncracked
concrete
Approvals/Listings
NOA 12-0625.05
Metro-Dade County
February 2020
2
KWIK-CON II+ Concrete and Masonry Screw
MATERIAL SPECIFICATIONS
Carbon steel expansion sleeves and spacer sleeves are manufactured from cold rolled steel.
Carbon steel anchors are zinc plated in accordance with ASTM B633, SC 1, Type III.
Stainless steel anchor components are manufactured from AISI Type 304 stainless steel.
MATERIAL SPECIFICATIONS
• Screws manufactured from 1018 to 1022 cold rolled steel case hardened to HRC 45 minimum
Carbon Steel with KWIK Cote
• Minimum tensile strength and yield strength for the 1/4-in. is 138 ksi and 137 ksi, respectively
Minimum tensile strength and yield strength for the 3/16-in. is 138 ksi and 137 ksi, respectively
KWIK Cote is a zinc-rich basecoat with an aluminum-rich topcoat.
KWIK Cote corrosion resistant coating
• Screws manufactured from AISI Type 410 stainless steel. Minimum tensile strength and yield strength for the
1/4-in. is 184ksi and 157 ksi, respectively
AISI Type 410 stainless steel1
• Minimum tensile strength and yield strength for the 3/16-in. is 194 ksi and 170 ksi, respectively
• Tapered flat head with #3 Phillips recess for 3/16- and 1/4-in. anchors
• Tapered flat head with T-25 TORX recess for 3/16-in. anchor
• Tapered flat head with T-27 TORX recess for 1/4-in. anchor
Head Styles
• 5/16-in. hex washer with internal T-25 TORX recess for 3/16- and 1/4-in.
anchors
• Maximum 0.507 in. for 3/16- and 1/4-in. tapered Philips flat head and 1/4-in. tapered T-27 TORX flat head
anchors
Head diameter
Maximum 0.385 in. for 3/16-in. tapered T-25 TORX flat head anch
Maximum 0.432 in. maximum for 3/16- and 1/4-in. T-25 TORX hex washer head ancho
• Nominal 3/16-in., Major dia. is 0.217 inches, Minor2 is 0.145 inches
Thread diameter
• Nominal 3/16-in. is 0.170 inches
Shank diameter
• Nominal 1/4-in. is 0.224 inches
1-1/4, 1-3/4, 2-1/4, 2-3/4, 3-1/4, 3-3/4, 4 (See ordering information section)
Lengths (in.)
• Trilobular, cold formed.
Thread design
• Nominal 3/16-in. have 8 tpi.
• Nominal 1/4-in. have 8 tpi.
Threads per inch
Inches of thread per fastene
1.875 inches maximun
• Ductility at 10° minimum
Bending capacity
This is not a controlled dimension.
2 Minoria teter i ate ail strength are the verage or ren sa meles. ment on a tested sa ripes: These are not minimum stel properties or mihimum manufacturing speciations
3
February 2020
HILTI
DESIGN INFORMATION IN CONCRETE PER ALLOWALBLE STRESS DESIGN
Table 1 - Tension and shear allowable loads in concrete 1,2
Nominal
f'. = 4,000 psi
f'. = 6,000 psi
f. = 2,000 psi
anchor
Nominal
Shear
Shear
Tension
Tension
embedment
Tension
Shear
diameter
Ib (kN)
Ib (kN)
Ib (kN)
Ib (kN)
Ib (kN)
(in.)
Ib (kN)
in. (mm)
185
260
280
100
125
260
3/16
(0.82)
(1.25)
(1.16)
(0.56)
(0.44)
(1.16)
(25)
265
325
295
275
300
260
1-3/4
3/16
(1.45)
(1.33)
(1.31)
(1.22)
(1.18)
(1.16)
(44)
540
275
240
325
190
390
1
1/4
(1.07)
(1.73)
(2.40)
(1.45)
(1.22)
(0.85)
(25)
600
600
525
475
425
560
1-3/4
1/4
(2.3)
(1.89)
(2.67)
(2.82)
(2.49)
(2.1)
(44)
Screws installed in holes drilled with Hilti TKC carbide bits.
2 Allowable loads are based on a safety factor of 4.
Table 2 - Tension and shear ultimate loads in concrete
Nominal
f'. = 6,000 psi
f'. = 4,000 psi
f'. = 2,000 psi
Nominal
anchor
Shear
Shear
Tension
Shear
Tension
Tension
embedment
diameter
Ib (kN)
Ib (kN)
Ib (kN)
Ib (kN)
Ib (kN)
lb (kN)
in. (mm)
(in.)
1,150
750
500
400
1,050
1
1,050
3/16
(5.12)
(3.34)
(2.22)
(4.67)
(1.78)
(25)
(4.67)
1,300
1,070
1,200
1,180
1,050
1,100
1-3/4
3/16
(5.25)
(4.76)
(5.34)
(5.78)
(4.67)
(4.89)
(44)
1,575
2,175
760
970
1,300
1,100
1
1/4
(9.68)
(4.31)
(7.01)
(4.89)
(25)
(3.38)
(5.78)
2,400
1,900
2,100
2,400
1-3/4
2,250
1,700
1/4
(10.7)
(8.5)
(9.3)
(10.7)
(44)
(70.0)
(7.56)
1 Screws installed in holes drilled with TKC bits.
Table 4 - Tension and shear allowable loads
Table 3 - Tension and shear allowable loads
in red brick1,2,3
in hollow block1,2,3,4
Nominal
Nominal
Nominal
anchor
Nominal
anchor
Tension
embedment
Shear
diameter
embedment
diameter
Shear
Tension
Ib (kN)
Ib (kN)
in. (mm)
Ib (kN)
(in.)
in. (mm)
Ib (kN)
(in.)
125
235
150
225
1
1
3/16
3/16
(0.56)
(1.05)
(25)
(0.67)
(1.00)
(25)
300
350
290
300
1-3/4
1-3/4
3/16
3/16
(1.56)
(1.33)
(1.29)
(1.33)
165
415
205
275
1/4
1/4
(1.85)
(0.91)
(25)
(1.22)
(0.73)
(25)
500
350
400
1-3/4
310
1-3/4
1/4
1/4
(2.22)
(44)
(1.38)
(1.56)
(44)
(1.78)
All values for anchors installed in hollow concrete masonry with a minimum prism strength of
1.500 psi. Concrete block may be lightweight, medium-weight or normal-weight conforming
The wite variations mounted in the compresser senior one ice on e
considered guide values.
to ASTM C90.
Allowable loads are based on a safety factor of 4.
2 Screws installed in holes drilled with TKB bits.
3 Installation in the mortar joints is outside the scope of the published data.
3 Allowable loads calculated using a factor of safety of 4.
4 Installation in the mortar joints is outside the scope of the published data.
Combined shear and tension loading
Load values are for anchors installed a minimum of sixteen diameters on center and
/ Va
a minimum edge distance of sixteen diameters. Anchor spacing may be reduced to
≤ 1.0
+
(N)
twelve diameters provided loads are reduced by 20 percent. Edge distance may be
Vrec
Nrec
reduced to six diameters provided loads are reduced by 20 percent in tension and
70 percent in shear.
INSTALLATION INSTRUCTIONS
Installation Instructions For Use (FU) / Operating Instructions (Ol) throughout the document are included with each product
package. They can also be viewed or downloaded online at www.hilti.com. Because of the possibility of changes, always verify that
downloaded FU are current when used. Proper installation is critical to achieve full performance. Training is available on request.
Contact Hilti Technical Services for applications and conditions not addressed in the (IFU)/Operating Instructions (Ol).
February 2020
4
KWIK-CON II+ Concrete and Masonry Screw
ORDERING INFORMATION'
KWIK-CON II+ fasteners
5/16 - in. Magnetic nut setter or T-25 TORX bit
Diameter
Description
Thread length
Total length
Shank length
3/16
KWIK-CON II+ 316-114 THWH
1-1/4
1-1/4
1-1/4
3/16
KWIK-CON II+ 316-114 THWH Bulk
1-1/4
1-3/4
1-3/4
KWIK-CON II+ 316-134 THWH
3/16
1-3/4
o0°
KWIK-CON II+ 316-134 THWH Bulk
1-3/4
3/16
3/16
KWIK-CON II+ 316-214 THWH
1-3/4
2-1/4
KWIK-CON II+ 316-234 THWH
3/16
1-3/4
2-3/4
1-3/4
KWIK-CON II+ 316-234 THWH Bulk
3/16
2-3/4
KWIK-CON II+ 316-314 THWH
1-1/2
3-1/4
3/16
1-3/4
2
1-3/4
KWIK-CON II+316-334 THWH
3-3/4
3/16
2-1/4
4
KWIK-CON II+ 316-4 THWH
1-3/4
3/16
5/16 - in. Magnetic nut setter or T-25 bit
Thread length
Diameter
Total length
Description
Shank length
0
1-1/4
1-1/4
KWIK-CON II+ 14-114 THWH
1/4
0
1-1/4
KWIK-CON II+ 14-114 THWH Bulk
1-1/4
1/4
0
1-3/4
1-3/4
1/4
KWIK-CON I|+ 14-134 THWH
1-3/4
1-3/4
1/4
KWIK-CON II+ 14-134 THWH Bulk
1-3/4
2-1/4
1/2
KWIK-CON II+ 14-214 THWH
1/4
1
2-3/4
1-3/4
KWIK-CON II+ 14-234 THWH
1/4
1
1-3/4
2-3/4
1/4
KWIK-CON II+ 14-234 THWH Bulk
1-3/4
1-1/2
3-1/4
KWIK-CON II+ 14-314 THWH
1/4
2
KWIK-CON II+ 14-334 THWH
1-3/4
3-3/4
1/4
2
3-3/4
1-3/4
KWIK-CON II+ 14-334 THWH Bulk
1/4
2-1/4
4
1-3/4
1/4
KWIK-CON II+ 14-4 THWH
1-1/4
1-1/4
KWIK-CON II+ 14-114 THWH Stainless Steel
1/4
1
2-3/4
1-3/4
KWIK-CON II+ 14-234 THWH Stainless Steel
1/4
T-25 TORX bit
Shank length
Diameter
Total length
Thread length
Description
1-1/8
1-1/4
3/16
KWIK-CON II+ 316-114 TH
0
1-5/8
KWIK-CON II+ 316-134 TH
1-3/4
3/16
0
1-3/4
1-5/8
KWIK-CON II+ 316-134 TFH Bulk
3/16
3/8
2-1/4
1-3/4
KWIK-CON II+ 316-214 TH
3/16
1-3/4
7/8
2-3/4
3/16
KWIK-CON II+ 316-234 TFH
1-3/4
2-3/4
7/8
KWIK-CON II+ 316-234 TFH Bulk
3/16
1-3/4
3-1/4
1-3/8
3/16
KWIK-CON II+ 316-314 TH
1-3/4
3/16
3-3/4
KWIK-CON II+ 316-334 TH
KWIK-CON II+ 316-334 TFH Bulk
3-3/4
1-3/4
3/16
4
KWIK-CON I|+ 316-4 TH
1-3/4
2-1/8
3/16
T-27 TORX bit
Diameter
Shank length
Thread length
Description
Total length
0
1-1/4
1-1/16
KWIK-CON II+ 14-114 TH
1/4
1-3/4
1-9/16
1/4
KWIK-CON II+ 14-134 TH
1-3/4
KWIK-CON II+ 14-134 TFH Bulk
1/4
1-9/16
5/16
1-3/4
KWIK-CON II+ 14-214 TFH
2-1/4
1/4
13/16
1-3/4
2-3/4
1/4
KWIK-CON II+ 14-234 TH
1-5/16
3-1/4
1-3/4
KWIK-CON II+ 14-314 TH
1/4
KWIK-CON II+ 14-314 TFH Bulk
1-3/4
3-1/4
1-5/16
1/4
3-3/4
1-3/4
KWIK-CON I|+ 14-334 TH
1/4
1-13/16
1-3/4
4
2-1/16
1/4
KWIK-CON II+ 14-4 TH
Total Length
Total Length
1 All dimensions in inches
Shank
Thread length
→ length |
5
February 2020
HILTI
KWIK-CON II+ fasteners
#3 Phillips bit
Description
Thread length
Shank length
Total length
Diameter
KWIK-CON II+ 316-114 PFH
1-1/16
1-1/4
3/16
KWIK-CON II+ 316-134 PFH
1-3/4
1-9/16
3/16
KWIK-CON II+ 316-214 PFH
3/16
2-1/4
1-3/4
5/16
KWIK-CON II+ 316-234 PFH
1-3/4
3/16
2-3/4
13/16
KWIK-CON II+ 316-314 PFH
1-3/4
1-5/16
3/16
3-1/4
KWIK-CON II+ 316-334 PFH
1-3/4
1-13/16
3/16
KWIK-CON II+ 316-4 PFH
2-1/16
3/16
1-3/4
KWIK-CON II+ 316-114 PFH Stainless Steel
3/16
1-1/16
1-1/4
13/16
KWIK-CON II+ 316-234 PFH Stainless Steel
3/16
2-3/4
1-3/4
AAAAA
#3 Phillips bit
Description
Diameter
Total length
Thread length
Shank length
KWIK-CON II+ 14-114 PFH
1-1/4
1-1/16
1/4
1-3/4
1/4
1-9/16
KWIK-CON II+ 14-134 PFH
5/16
2-1/4
1/4
1-3/4
KWIK-CON II+ 14-214 PFH
KWIK-CON I|+14-234 PFH
1/4
2-3/4
13/16
1-3/4
1/4
3-1/4
1-5/16
1-3/4
KWIK-CON II+ 14-314 PFH
KWIK-CON II+ 14-334 PFH
1-13/16
3-3/4
1/4
1-3/4
KWIK-CON II+ 14-4 PFH
4
1/4
1-3/4
2-1/16
KWIK-CON Il+ hex driver system
Qty / pack
Description
1
KWIK-CON Hex Driver Deluxe Kit
KWIK-CON Hex Driver
5/16-in. Hex Driver for all THWH
5/16-in. Hex Nut Setter/Depth Locator
Insert Bit Holder/Depth Locator
#3 Phillips Driver for all PFH
T-25 TORX Driver for 3/16-in. TH
T-27 TORX Driver for 1/4-in. TH
KWIK-CON Il+ matched tolerance drill bits
Description
For 1/4-in. KWIK-CON II+ Applications in normal-weight concrete
TKC Large Concrete Bit SDS+ Hex
TKC Large Concrete Bit Smooth Shank
For 1/4-in. KWIK-CON Il+ Applications in lightweight concrete, brick or block
TKB Large Block Bit SDS+ Hex
TKB Large Block Bit Smooth Shank
For 3/16-in. KWIK-CON IIt Applications in normal-weight concrete
TKC Small Concrete Bit SDS+ Hex
TKC Small Concrete Bit Smooth Shank
For 3/16-in. KWIK-CON Il+ Applications in lightweight concrete, brick or block
TKB Small Block Bit SDS+ Hex
TKB Small Block Bit Smooth Shank
Total Length
Total Length
thread length
thread length
Shank
Shank
Thread length
length
Thread length
length
1 All dimensions in inches.
February 2020
6
Hilti, Inc. [phone removed]
Hilti (Canada) Corporation [phone removed]
en español [phone removed]
HILTI
www.hilti.com
www.hilti.ca
HILTI
The following pages are an excerpt from the North American Produc
Technical Gude, Volume 1: Dırect Fastening lechnical Gulde, Edition 21
Please refer to the publication in its entirety for complete details on this
product including data development, base materials, general suitability,
installation, corrosion, and product specifications.
Direct Fastening Technical Gude, Edition 21
To consult directly with a team member regarding our direct fastening
products, contact Hilti's team of technical support specialists between
the hours of 7:00am - 5:00pm CST.
US: [phone removed] or [email removed]
CA: [phone removed] ext. 6 or [email removed]
Hilti, Inc.
7250 Dallas Parkway, Suite 1000
Plano, Texas 75024
[phone removed] | www.hilti.com
HILT
3.6.2.1
Product description
3.6.2 SELF-DRILLING SCREWS
Material specifications
3.6.2.2
3.6.2.1 PRODUCT DESCRIPTION
Technical data
3.6.2.3
Product features:
Hilti self-drilling screws are designed
Installation instructions
3.6.2.4
to drill their own hole in steel base
• Hex head for metal-to-metal
materials up to 1/2" thick. These screws
3.6.2.5
Ordering information
applications
are available in a variety of head styles,
• Flush head for wood-to-metal
thread lengths and drill-flute lengths for
applications
screw diameters #6 through 1/4". Hilti
• For metal from 0.035" to
0.500" thick
self-drilling screws meet ASTM C1513,
ASTM C954 and SAE J78 standards,
• Winged reamers for wood over
1/2" thick
as applicable.
• Stitch screws for light gauge
metal-to-metal
• Sealing screws for water
Listings/Approvals
resistant fastenings
ICC-ES (International Code Council)
ESR-2196 with LABC/LARC Supplement
(Steel and Metal Screws)
ESR-3891 with LABC/LARC Supplement
(Interior Finishing/Drywall Screws)
3.6.2.2 MATERIAL SPECIFICATIONS
Material
ELA
ASTM A510 Grade 1018-1022
GODBS
Heat treatment
Case hardened and tempered
• Sizes 8, 10 and 12: 0.004" to 0.009" case depth
• Size 1/4": 0.005" to 0.011" case depth
ICC-ES ESR-2196 and ESR-3891
Plating
together, provide IBC recognition of
Refer to Section 3.6.2.5 for screw coating information.
Hilti's Self-Drilling Screw fasteners for
Warning: Because of the potential for delayed hydrogen assisted stress corrosion cracking,
most common applications (e.g. CFS
many hardened steel fasteners are not recommended for use with dissimilar metals or
connections, gypsum to CFS, etc.),
chemically treated wood when moisture may be present or in corrosive environments. For further
including HWH, HHWH, PPH, PPFH,
information, contact Hilti Technical Support at [phone removed].
PBH, PWH, PTH, PPCH, TPCH and
PFTH head style screws. Wood screws
are not covered in the ICC-ER's.
3.6.2.3 TECHNICAL DATA
Ultimate tensile strengths - pullout (tension), Ib (kN) ,2,3,4,5,6,7
Thickness of steel member not in contact with the screw head, ga (in.)
Nominal
Screw
10
16
12
18
14
20
diameter
designation
in.
(0.105)
(0.135)
(0.075)
(0.048)
(0.036)
(0.060)
395
555
715
320
250
190
0.138
#6
(3.18)
(1.76)
(2.47)
(0.85)
(1.11)
(1.42)
780
435
345
275
605
210
#7
0.151
(3.47)
(1.93)
(2.69)
(0.93)
(1.22)
(1.53)
845
225
375
660
470
300
#8
0.164
(3.76)
((2.94)
(1.67)
(1.33)
(2.09)
(1.00)
350
435
980
765
260
545
#10
0.190
(3.40)
(1.93)
(2.42)
(1.16)
(1.56)
(4.36)
870
[phone removed]
495
295
#12
0.216
(1.76)
(2.76)
(2.20)
(4.98)
(3.87)
(1.31)
460
[phone removed]
1290
345
0.250
1/4 in.
(3.18)
(4.45)
(2.05)
(1.53)
(5.74)
(2.56)
1 The lower of the ultimate pullout, pullover, and tension fastener strength of screw should be used for design.
2 Load values based upon calculations done in accordance with Section J4 of the AISI S100
3 AISI S100 recommends a safety factor of 3.0 be applied for allowable strength design, a factor of 0.5 be applied for LRFD design or a $ factor of 0.4 be applied for LSD design.
4 ANSI/ASME standard screw diameters were used in the calculations and are listed in the tables.
5 The screw diameters in the table above are available in head styles of pan, hex washer, pancake, flat, wafer and bugle.
6 The load data in the table is based upon sheet steel with F, = 45 ksi. For F, = 55 ksi steel, multiply values by 1.22. For F, = 65 ksi steel, multiply values by 1.44.
7 Refer to Section 3.6.2.5 to ensure drilling capacities.
212
Direct Fastening Technical Guide, Edition 21
Ultimate tensile strengths - pullover (tension), lb (kN) 1.23,4,5,6,7
Thickness of steel member in contact with the screw head, ga (in.)
Washer or
Screw
12
18
10
16
14
20
22
head diameter
designation
in.
(0.135)
(0.075)
(0.048)
(0.036)
(0.060)
(0.030)
(0.105)
Hex Washer Head (HWH)
1000
1000
1000
[phone removed]
675
#8
0.335
(4.45)
(4.45)
(4.45)
(4.45)
(3.63)
(3.00)
(4.45)
1370
1290
1370
1370
1370
805
970
#10
0.399
(5.74)
(6.09)
(6.09)
(6.09)
(6.09)
(4.31)
(3.58)
1340
2100
1680
2325
2325
1010
835
#12-14
0.415
(9.34)
(10.34)
(4.49)
(5.96)
(10.34)
(7.47)
(3.71)
1340
2940
1010
1680
2[phone removed]
#12-24
0.415
(16.81)
(13.08)
(5.96)
(9.34)
(4.49)
(3.71)
(7.47)
1620
2030
2530
3540
4560
1010
1220
0.500
1/4 in.
(7.21)
(20.28)
(11.25)
(13.75)
(9.03)
(5.43)
(4.49)
Phillips Pan Head (PPH)
980
1000
1000
1000
1000
735
615
#7
0.303
(4.45)
(3.27)
(4.45)
(4.36)
(2.74)
(4.45)
(4.45)
1000
1000
[phone removed]
1000
630
#8
0.311
(4.45)
(4.45)
(4.45)
(3.36)
(4.45)
(2.80)
(4.45)
1180
1370
1370
1370
1370
740
885
0.364
#10
(6.09)
(5.25)
(6.09)
(6.09)
(6.09)
(3.29)
(3.94)
Phillips Truss Head (PTH)
1000
1000
1000
1000
1000
1000
830
#8
0.411
(4.45)
(4.45)
(4.45)
(4.45)
(4.45)
(4.45)
(3.69)
1390
1390
1390
1390
1050
1390
875
#10
0.433
(6.18)
(6.18)
(6.18)
(6.18)
(6.18)
(4.67)
(3.89)
Phillips Pancake Head (PPCH)
1325
1370
1370
[phone removed]
830
0.409
#10, #12
(5.89
(6.09)
(6.09)
(6.09)
(6.09)
(4.43)
(3.69)
Phillips Flat Truss Head (PFTH)
1180
1475
2170
2170
1840
740
885
0.364
#10
(9.65)
(6.56)
(9.65)
(8.18)
(3.94)
(3.29)
(5.25)
The lower of the ultimate pullout, pullover, and tension fastener strength of screw should be used for design
2 Load values based upon calculations done in accordance with Section J4 of the AISI S100
AISI S100 recommends a safety factor of 3.0 be applied for allowable strength design, ad factor of 0,5 be applied for RFD design or a d factor of 0.4 be applied for LSD design.
ANS/ASME standard screw head diameters were used in the calculations and are listed in the tables.
he load data in the table is based upon sheet steel with F.=
6
Refer to Section 3.6.2.5 for drilling capacities.
Nominal ultimate fastener strength of screw
Torsional strength 2
Min. torsional strength
Nominal fastener strength
Nominal
Size
Screw
in-lb (Nm)
near, r
diameter
Tension, Pts
designation
(KIN)
6-20
24
(2.7)
(in.)
Ib (kN)"
890
1000
(4.3)
38
(4.45)
#6-20
0.138
7-18
(3.96)
(4.8)
42
890
1000
0.151
8-18
(4.45)
#7-18
(3.96)
1000
1170
61
(6.9)
#8-18
0.164
10-12
(4.45)
(5.20)
61
1645
2170
0.190
10-16
(6.9)
(9.65)
#10-12
(7.32)
(6.9)
61
10-18
1215
0.190
1370
#10-16
(6.09)
(5.40)
1645
65
0.190
(7.3)
10-24
#10-18
(6.18)
1390
(7.32)
1880
92
(10.4)
0.216
#12-14
12-14
2325
(8.36)
(10.34)
2285
100
#12-24
0.216
(11.3)
12-24
3900
(17.35)
(10.16)
150
2440
(17.0)
1/4-14
4580
0.250
(20.37)
(10.85)
1/4 in.
156
(17.6)
1/4-20
The lower of the ultimate pullout, pullover, and tension fastener strength of screw should be used for design. The Pullout and
Pullover tables in this section have already been adjusted where screw strength governs.
1 Based on screw only. Does not consider base material
limitations.
2 The lower of the ultimate shear fastener strength and shear bearing should be used for design. The Shear Bearing table in this
section has already been adjusted where screw strength governs.
2 Values in table are ultimate torsional strengths.
To obtain maximum setting torque, multiply values in table
3 AISI S100 recommends a safety factor of 3.0 be applied for allowable strength design, a factor of 0.5 be applied for RFD
design or a $ factor of 0.4 be applied for LSD design.
by 0.66.
213
HILT!
Ultimate shear strengths - bearing (shear), lb (kN)1.234,5,6,7
Thickness of steel
Thickness of steel member not in contact with the screw head, ga (in.)
Nominal
member in contact with
Screw
diameter
screw head
designation
14 (0.075)
≥ 12(0.105)
18(0.048)
in.
20 (0.036)
16 (0.060)
ga (in.)
660
660
660
(2.94)
(2.94)
500
660 (2.94)
(2.22)
(2.94)
20(0.036)
880
880
770
500
(3.11)
(3.91)
(3.91)
(2.22)
880(3.91)
18(0.048)
#7
0.151
(2.22)
770
(3.96)
(3.96)
890
890
500
(3.11)
890 (3.96)
≥ 16(0.060)
715
715
(3.18)
715
(2.34)
715(3.18)
525
(3.18)
(3.18)
20(0.036)
(4.25)
805
955
(2.34)
955
(3.58)
525
#8
(4.25)
955 (4.25)
18(0.048)
0.164
805
(2.34)
1120(4,98)
1170(5.20)
525
(3.58)
1170(5.20)
≥ 16 (0.060)
830
830
(3.69)
830(3.69)
(2.51)
565
(3.69)
830 3.69)
20(0.036)
865
1110(4.94)
(3.85)
1110(4.94)
565(2.51)
1110(4.94)
18(0,048)
0.190
#10-12
1390(6.18)
865
1210(5.38)
(3.85)
1390(6.18)
565 (2.51)
16(0.060)
865
1210(5.38)
(3.85)
1645(7.32)
1645(7.32)
565 (2.51)
≥ 14(0.075)
830
(3.69)
830(3.69)
830
565
(3.69)
(2.51)
830 (3.69)
20(0.036)
865
1110(4.94)
(3.85)
1110(4.94)
1110(4.94)
565(2.51)
0.190
#10-16
18(0.048)
865
1215(5.40)
(3.85)
1215(5.40)
1210 (5.38)
≥ 16(0.060)
565(2.51)
830
830
830
(3.69)
830
565
(2.51)
(3.69)
(3.69)
(3.69)
20(0.036)
1110
1110
1110
(4.94)
(4.94)
(3.85)
865
565
(4.94)
(2.51)
18(0.048)
#10-18
0.190
1390
1390
865
(3.85)
1210
(6.18)
(6.18)
(5.38)
(2.51)
565
16(0.060)
1645
1645
865
(3.85)
1210
(2.51)
(7.32)
(7.32)
(5.38)
565
≥ 14(0.075)
945
945
930
945
(4.20)
(4.20)
(4.20)
(2.67)
(4.14)
600
20(0.036)
[phone removed]
(5.60)
1260
(5.60)
(2.67)
(5.60)
(4.11)
600
18(0.048)
0.216
#12-14
1290
1570
(6.98)
925
1570
(6.98)
(4.11)
(5.74)
600
(2.67)
16(0.060)
1290
1800
(8.36)
(8.00)
1880
925
(5.74)
(4.11)
(2.67)
600
≥ 14(0.075)
945
945
(4.20)
945
930
(4.20)
(4.20)
(4.14)
(2.67)
600
20(0.036)
1260
1260
1260
(5.60)
(5.60)
(5.60)
925
(2.67)
(4.11)
600
18 (0.048)
1570
[phone removed]
(6.98)
(6.98)
(2.67)
(4.11)
(5.74)
600
0.216
16(0.060)
#12-24
1970
1800
(8.76)
(2.67)
925
1290 (5.74)
(8.00)
(4.11)
600
14(0.075)
2285
1800
(10.16)
1290
(2.67)
925
(5.74)
(8.00)
(4.11)
600
≥ 12 (0.090)
1090
1090
1090
1020
(4.54)
(4.85)
(4.85)
(2.87)
(4.85)
645
20 (0.036)
1460
1460
(6.49)
1400
995
(6.23)
(6.49)
(2.87)
645
(4.43)
18(0.048)
[phone removed]
(8.10)
1820
(6.18)
(8.10)
(2.87)
645
(4.43)
0.250
16(0.060)
1/4 in.
995
1940
1390
2280(10.14)
(8.63)
(6.18)
(4.43)
14(0.075)
645 (2.87)
995
1390
2440(10.85)
1940
(6.18)
(8.63)
645(2.87)
(4.43)
≥ 12(0.090)
1 The lower of the ultimate shear bearing and shear fastener strength of screw should be used for desigr
2 Load values based upon calculations done in accordance with Section J4 of AISI S100
4 ANSAS standards readia mater ere used iptied car alans earl ted in the factor of 0.5 be appled for LAFD design or a factor of 0.4 be applied for LSD design.
5 Load values in table are for Hex Washer Head (HWH and HHH), Phillips Pan Head (PPH), Phillips Truss Head (PTH), Phillips Pancake Head (PPCH), and Phillips Flat Truss Head (PFTH)
stvle screws. Phillips Bugle Head (PBH) and Phillips Wafer Head (PWH) styles are not covered by this table because they are not intended for attachment of steel to steel.
6 The load data in the table is based upon sheet steel with F = 45 ksi. For F=55 ksi steel, multiply values by 1.22. For F=65 ksi steel, multiply values by 1.44.
7 Refer to Section 3.6.2.5 to ensure drilling capacities.
3.6.2.4 INSTALLATION INSTRUCTIONS
For general discussion of Hilti screw fastener installation, reference Section 3.6.1.7.
For allowable diaphragm shear loads and stiffness values for steel roof or floor deck utilizing Hilti self-drilling screws as frame or
sidelap fasteners, reference Section 3.5 and download Hilti's Profis DF software at www.hilti.com/decking (US), or www.hilti.ca
(Canada).
To estimate the number of sidelap screws on a steel roof or floor deck project, reference Section 3.5.1.5.
Warning: Because of the potential for delayed hydrogen assisted stress corrosion cracking, many hardened steel fasteners are not recommended
for use with dissimilar metals or chemically treated wood when moisture may be present or in corrosive environments. For further information,
contact Hilti Technical Support at [phone removed].
214
Direct Fastening Technical Guide, Edition 21
3.6.2.5 ORDERING INFORMATION
Collated self-drilling screws
Light/medium gauge metal applications (sidelap)
Drilling Capacity
Maximum Total
Thread
Box qty
Min
Max
Coating?
Recess
Thickness (MT)
Description
length
0.095"
250
3/32"
Zinc-2
0.018"
0.100"
5/16"
S-SLC 01 M HWH Collated
5/8"
Zinc-1
250
5/16"
0.028"
S-SLC 02 M HWH Collated
0.375"
3/4"
3/8"
0.120"
0.028"
250
5/16"
0.188"
0.120"
Zinc-1
S-MD 10-16 x 7/8 HWH Collated
3/8"
3/16"
Medium/heavy gauge metal applications (frame fastener)
Drilling capacity
Thread
Maximum total
Max
Coating?
Min
Box qty
Recess
Description
length
thickness (MT)'
250
Zinc-1
0.375"
0.175"
3/8'
5/16"
1/2"
0.110"
S-MD 10-16 x 3/4 HWH#3 Collated
250
0.312"
0.375"
Zinc-1
0.175"
3/8"
1/2'
5/16"
S-MD 12-24 x 7/8 HWH#4 Collated
1 Refer to Figure in Section 3.6.1.5.
2 For coating abbreviations, Zinc-1 = EN/ISO 4042 A3F; Zinc-2 = Cr3 + (Cr6 + free) 8-14 um. For more information on corrosion resistance, reference
Section 3.6.1.6.
HWH
PWH
#5 Point
Stitch
HWH
HWH
PPH
with bonded
with wings
Kwik-Seal
washer
Single Self-Drilling Screws
Sidelap (unsupported metal sheets)
Drilling capacity
Maximum total
Thread
Max
Recess
Box qty
Min
length
Coating?
thickness (MT)'
Description
3000
0.120"
Zinc-1
5/16
3/8"
0.375"
0.028"
3/4"
S-MD 12-14x1 HHWH Stitch
6000
0.188"
0.120"
Zinc-1
5/16"
0.028"
3/16"
3/8"
S-MD 10-16x7/8 HHWH Pilot Point
0.313"
2500
Kwik-Cote
0.028"
5/16"
0.140"
1/2"
5/16"
S-MD 1/4-14x7/8 HWH Stitch Kwik-Seal
1 Refer to Figure in Section 3.6.1.5.
2 Section 3. breviations, Zinc-1 - EN/SO 4042 A3F; Kik Cote - Proprietary Coating, Section 3,6.2.2 For more information on corrosion resistance, reterence
215
HILTI
Light gauge applications: steel to steel
Drilling Capacity
Thread
Maximum Total
Box Qty
length
Max
Coating?
Min
Thickness (MT)'
Recess
Description
1000
0.035"
0.125"
0.100"
1/8'
1/4"
S-MD 8-18x1/2 HWH #2
1/4"
Zinc-1
0.035"
0.100"
1/4"
S-MD 8-18x3/4 HWH #2
3/8"
Zinc-1
1000
1/2"
0.375"
0.035"
Zinc-1
1/8"
0.100"
PHL #2
1000
1/4"
S-MD 8-18x1/2 PPH #2
0.125"
0.035"
0.110"
0.188"
5/16"
5/16"
8500
3/16"
Zinc-1
S-MD 10-16x1/2 HWH #2
0.035"
0.110"
5/16"
6500
0.313"
Zinc-1
5/16"
1/2"
S-MD 10-16x3/4 HWH #2
0.035"
0.500"
0.110"
S-MD 10-16x1 HWH #2
1/2"
5000
Zinc-1
5/16"
3/4"
Refer to Figure in Section 3.6.1.5.
2 For coating abbreviations, Zinc-1 - EN/ISO 4042 A3F For more information on corrosion resistance, reference Section 3.6.1.6.
Light/medium gauge metal applications
Drilling capacity
Maximum total
Max
Box Qty
Min
Recess
thickness (MT)'
Description
0.175"
7500
0.110"
3/16"
S-MD 10-16x5/8 HWH #3
0.187"
5/16"
0,175"
0.110"
6500
3/8"
0.375"
S-MD 10-16x3/4 HWH #3
5/16"
0.375"
0.110"
6500
0,175"
3/8"
5/16"
S-MD 10-16x3/4 HHWH #3
-
0.110"
5/8"
0,175"
0.625"
S-MD 10-16x1 HWH #3
5000
5/16"
0.110"
0.175"
0.875"
4000
7/8"
S-MD 10-16x1 1/4 HWH #3
5/16"
0.110"
0,175"
1-1/8"
4000
5/16"
1.125"
S-MD 10-16x1 1/2 HWH #3
0.110"
0.175"
0.313"
7500
S-MD 10-16x5/8 PPH #3
PHL #2
5/16"
0.110"
6500
0.375"
0,175"
PHL #2
3/8"
S-MD 10-16x3/4 PPH #3
1183233
0.175"
5/16"
Zinc-1
PHL #2
0.313"
0.110"
S-DD 10-16x5/8 PPCH #3
7500
Zinc-1
PHL #2
7500
0.110"
0.175"
3/8"
0.375"
S-DD 10-12x3/4 PFTH #3
0.110"
0.175"
5000
Zinc-1
0.375"
3/8"
PHL #2
S-DD 10-18x3/4 PTH #3
5/16"
5000
Zinc-1
0.110"
0.210"
0.313"
5/16"
S-MD 12-14X3/4 HWH #3
0.110"
0.210"
0.562"
Zinc-1
9/16"
3000
S-MD 12-14x1 HWH #3
5/16"
0.210"
Zinc-1
1-1/16"
0.110"
2500
1.062"
5/16"
S-MD 12-14x1 1/2 HWH #3
0.210"
Zinc-1
1.562"
0.110"
1-9/16"
2000
5/16"
S-MD 12-14x2 HWH #3
0.110"
1/2"
0.500"
0.210"
Zinc-2
TX 25 HF
7500
S-DD 12-14x1 TPCH #3
Zinc-1
0.110"
0.220"
0.313"
4000
5/16"
3/8"
S-MD 1/4-14x3/4 HWH #3
0.220"
Zinc-1
3000
3/8"
9/16"
0.562"
S-MD 1/4-14x1 HWH #3
0.110"
Zinc-1
0.220"
2000
1.062"
0.110"
3/8"
1-1/16"
S-MD 1/4-14x1 1/2 HWH #3
Zinc-1
0.110"
0.220"
3/8"
1.562"
1000
1-9/16"
S-MD 1/4-14x2 HWH #3
3000
0.110"
0.210"
Kwik-Cote
0.125"
5/16"
1/8"
S-MD 12-14x3/4 HWH #3 Kwik-Seal
2500
Kwik-Cote
0.110"
0.210"
S-MD 12-14x1 HWH #3 Kwik-Seal
5/16"
318"
0.375"
2000
5/8"
0.110"
Kwik-Cote
0.210"
0.625"
5/16"
S-MD 12-14x1 1/4 HWH #3 Kwik-Seal
7/8"
Kwik-Cote
2000
0.210"
0.110"
0.875"
5/16"
S-MD 12-14x1 1/2 HWH #3 Kwik-Seal
1500
5/16"
Kwik-Cote
0.210"
0.110"
1.375'
S-MD 12-14x2 HWH #3 Kwik-Seal
1-3/8"
2000
0.375"
3/8'
Kwik-Cote
3/8"
0.110"
0.220"
S-MD 1/4-14x1 HWH #3 Kwik-Seal
1500
| Kwik-Cote
3/8'
0.875"
0.110"
7/8"
0.220"
S-MD 1/4-14x1 1/2 HWH #3 Kwik-Seal
2 For co fig are ir sections, 2in- - EN/SO A3F; Zinc-2 - Cra+ (Crt free) 8-14 um, Kwik-Cote - Proprietary Coating, Section 3,622. For more information on corosion resistance,
Warning: Because of the potential for delayed hydrogen assisted stress corrosion cracking, many hardened steel fasteners are not recommended
for use with dissimilar metals or chemically treated wood when moisture may be present or in corrosive environments. For further information,
contact Hilti Technical Support at [phone removed].
216
Direct Fastening Technical Guide, Edition 21
Single self-drilling screws - heavy gauge metal applications
Drilling capacity
Thread
Maximum total
Max
length
Box Qty
Min
Description
Coating?
thickness (МТ)
Recess
4500
S-MD 12-24x7/8 HWH #4
1/4"
0.175"
0.250"
0.250"
Zinc-1
5/16"
1/2"
0.625"
0.250"
3500
Zinc-1
5/8"
0.175"
5/16"
S-MD 12-24x1 1/4 HWH #4
3/4"
0.437"
4000
S-MD 12-24x1 1/4 HWH #5
5/16"
Zinc-1
0.250"
7/16"
0.500"
1/2'
4000
KwikCote
0.313"
0.500"
0.250"
1/2"
5/16"
5/16"
S-MD 12-24x1 1/4 HWH #5 Kwik-Cote
KwikCote
S-MD 12-24x2 HWH #5 Kwik-Cote
0.500"
2000
1.187"
0.250"
1-1/4"
1-3/16"
5/16"
1000
KwikCote
S-MD 12-24x3 HWH #5 Kwik-Cote
0.500"
2.187"
2-1/4"
0.250"
5/16"
2-3/16"
S-MD 12-24x1 1/4 HWH #5 Kwik-Cote
2500
0.500"
0.313
5/16"
KwikCote
0.250"
1/2"
5/16"
Bond Washer
1 Refer to Figure in Section 3.6.1.5.
2 For coating abbreviations, Zinc-1=EN/ISO 4042 AF; Kwik Cote = Proprietary Coating, Section 3.6.2.2. For more information on corrosion resistance, reference
Section 3.6.1.6.
Single self-drilling screws - heavy gauge metal applications
Drilling capacity
Thread
Maximum total
Max
length
Min
Recess
Coating? Box Qty
Description
thickness (MT)
Wood Drill Screws
Decking Screws (Plywood to Framing)
BP
PHL #2
S-WD 8-18x1 5/16 PFH #3
6000
1/2"
0.050"
0.500"
1/2"
0.140"
S-WD 8-18x1 15/16 PFH #3
BP
4000
0.050"
5/8"
0.140"
PHL #2
3/4"
0.750"
0.625"
6000
S-WD 10-24x1 PWH #3
0.175"
PHL #2
3/4"
0.050"
Zinc-1
5/8"
0.875"
5000
Zinc-1
0.050"
S-WD 10-24x1 1/4 PWH #3
1"
0.175"
PHL #2
7/8"
3500
1.125"
Zinc-1
S-WD 10-24x1 1/2PWH #3
0.175"
PHL #2
1-1/4"
1-1/8"
0.050"
Winged Reamer Wood Drill Screws
4000
0.050"
0.175"
1"
0.750"
PHL #2
Zinc-1
S-WW 10-24x1 7/16 PWH #3 wings
3/4"
2000
1-3/8"
0.050"
S-WW 12-24x2 PFH #4 wings
PHL #2
Zinc-1
0.232"
1-1/4"
1.250"
2"
Zinc-1
PHL #2
1.750"
0.050"
0.232"
1-3/4"
S-WW 12-24x2 1/2 PFH #4 wings
1500
Zinc-1
1000
0.050"
2"
2-1/4"
2.000"
PHL #2
0.250"
S-WW 14-20x2 3/4 PFH #4 wings
1 Refer to Figure in Section 3.6.1.5.
For coating abbreviations, Zinc-1 = EN/ISO 4042 AF; GP = Grey Phosphate. For more information on corrosion resistance, reference Section 3.6.1.6.
Warning: Because of the potential for delayed hydrogen assisted stress corrosion cracking, many hardened steel fasteners are not recommended
for use with dissimilar metals or chemically treated wood when moisture may be present or in corrosive environments. For further information,
contact Hilti Technical Support at [phone removed].
217
HILTI
Drywall applications (drywall to steel, framing and lathing screws)
Application
Box qty
Description
Coating'
Fastening Drywall, plywood, insulation,
DGP
6 × 1 PBH SD2
10,000
etc. to metal studs from 14 ga to 20 ga
6 × 1 PBH SD Z2
10,000
Zinc
10,000
DGP
6 × 1-1/8 PBH SD2
Zinc
6 × 1-1/8 PBH SD Z
DGP
8,000
6 × 1-1/4 PBH SD2
8,000
Zinc
6 × 1-1/4 PBH SD Z
6 x 1-1/4 PBH SD CRC2
CRC
8,000
6 × 1-5/8 PBH SD2
DGP
5,000
6 × 1-5/8 PBH SD Z2
Zinc
5,000
4,000
DGP
6 × 1-7/8 PBH SD2
4,000
6 × 1-7/8 PBH SD Z2
Zinc
6 × 1-7/8 PBH SD CRC
4,000
CRC
6 × 2 PBH SD?
GP/DGP
4,000
Zing
6 × 2 PBH SD Z2
4,000
8 x 2-3/8 PBH SD
GP
2,500
2,500
Zinc
8 × 2-3/8 PBH SD zinc
1,600
GP
8 × 2-5/8 PBH SD
8 x 2-5/8 PBH SD zinc
Zinc
1,600
8 x 3 PBH SD
GP
1,400
8 × 3 PBH SD zinc
1,400
Zinc
GP
10,000
7 x 7/16 PPFH SD Framer
Fastening stud to track
Zinc
7 × 7/16 PPFH SD Farmer Zinc
from 14 ga to 20 ga
8 × 1/2 PPH SD Framer Zinc
Zinc
10 × 5/8 PPCH SD Framer
7,500
Zinc
7,500
Zinc
10 x 3/4 PFTH SD Framer Zinc
5,000
10 x 3/4 PTH SD Framer Zinc
Zinc
8 × 1/2 PTH SD Lathing Zinc
Zing
Fastening wire lath to 14 ga to 20 ga
10,000
Zing
10,000
8 x 3/4 PTH SD Lathing Zinc
8 x 1 PTH SD Lathing Zinc
8,000
Zinc
Zinc
8,000
8 x 1-1/4 PTH SD Lathing Zinc
DGP
6 × 1-5/8 SFH SD
Fastening wood trim and base
5,000
6 × 2-1/4 SFH SD Zinc
3,000
to 14 ga to 20 ga studs
Zinc
1 For coating abbreviations, GP = Grey phosphate per EN ISO 3892; DGP - Dark Grey phosphate per EN ISO 3892; zinc = electroplated zine coating; CRC = Proprietary Duplex Coating. For
more information on corrosion resistance, reference Section 3.6.1.6.
2 Available in both single screw and collated screws.
The importance of IBC compliant screws.
ICC-ES ESR-2196 (Steel and Metal screw report) and ESR-3891 (Interior Finish/Drywall screw report) provides IBC recognition of
Hilt's Self-Drilling Screw Fasteners. This recognition was based on a comprehensive and rigorous independent evaluation of Hilt's
Self-Drilling Screw Fasteners to the latest IBC code requirements in ICC-ES AC118 Acceptance Criteria for Self-Tapping Screw
Fasteners, as well as the AISI S904 and AISI S905 test standards.
AC118 provides the IBC code recognition and quality assurance for screw fasteners. ICC-ES ESR-2196 recognizes Steel and
Metal Hilti screws which are used to connect cold-formed steel members together. ICC-ES ESR-3891 recognizes Interior Finish/
Drywall screws which are used to connect gypsum board materials to cold-formed steel base material cover the HWH, HHWH,
PPH, PPFH, PBH, PWH, PTH, PPCH, TPCH and PFTH head style Hilti screws.
To ensure IBC compliance of screws on your next project, reference ESR-2196 and ESR-3891.
ES
218
Signed Letter of Approval
Harvard Collection, LLC, C/o Regency Centers Corp.,
On behalf of the
_ 1,
(Building / Company)
John Fitzpatrick
_, approve of the following exterior signs, design, &
(Building Owner Name)
pricing to be produced and installed by Boston Building Wraps within the next few months.
(Following permit approval)
We approve of the attached above to be installed onto our building located at
MA
Cambridge
20 Brattle Street.,
(State)
(Street Address)
HARVARD COLLECTION LLC
a Delaware limited liability company
Regency Centers, L.P.,
a Delaware limited partnership
Its: Managing Member
By:
Regency Centers Corporation,
a Florida corporation
Its: General Partner
(Signature)
Vice President, Project Management
6/2/2022
Sign 1: $11,900 (T)
Custom Fabricated Internally LED Lit Blade Sign (24 Sq Ft | Approx. 200 Pounds)
STENCIL CUT OUT
2" FRAME
(typical)
THE ABBOT
THE ABBOT
1504)
Office
1-9 3/4
Office
(21.7)
Logo 1
Logo 1
BACK OF SIGN
Office
1-93/4"
Office
2' DEEP BACKER PANE
(24.7)
Logo 2
7'-0"
21W x 33
Logo 2 1
6'-5"
PAINTED BM - ROCKY COAS
(84.0")
(77.0")
1'-9 34"
PRINT/CUT VINY
(21.7")
TENANT LOGO
CENTRAL REEK GYM
CENTRAL ROCK GYM
11 3/4"
1117"
1'-8"
120.007
2'-0"
(24.0")
Front View
2'-0"
1'-9"
210 T
(24.0")
- 2. FRONT SIGN
1-10 ½"
(22.5")
- ELECTRICAL FEEDS
INTO BLADE SIGN
- 240% +
- EASED EDGES
(typical)
Top View
EXISTING MASONRY
5mm STAINLESS STEEL
LETTERS - NON-LIT
FABRICATED ALUMINUM
BLADE SIGN
MOUNTING BRACKET
- EXISTING METAL
PANEL
- 1/2" THREADED ROD
ANCHORS W/HILTY
(8,0")
• 1/2" THREADED ROD ANCHORS
• 2" DEEP FABRICATED
W/HILTY ADHESIVE
BACKER PANEL
2'-9"
4-1"
(49.0") (33.0")
FINAL QUANTITY AND LOCATIONS TBD
- PIN MOUNTED TO
BASED ON FINAL STRUCTURAL DRAWING
BACKER PANEL
Connection Detail
POWER SUPPLY
WEEP HOLES
*•MOUNTED FLUSH WITH BOTTOM OF METAL PANEL***
Jim in
X
Side View
(Signature)
6/2/2022
Sign 2: $7,700 (T)
Custom Fabricated Internally LED Lit Front Sign (7.35 Sq Ft | Approx. 210 Pounds)
20
BRATTLE
Perspective View
5'-4"
(64.0")
2-6%
CONDUIT-
ELECTRICAL FEEDS
INTO BLADE SIGN
2° DEEP ALUMINUM
2'-8"
BACKER PANEL
PAINTED TO MATCH
(32.0")
IN SIGN BAND
BM - ROCKY COAST
20
2" DEEP FABRICATED
STAINLESS STEEL LETTERS
BRUSH BRONZE RETURNS
BRATTLE
WHITE FACES
25
5-0%*
(60.9*)
Front View
EXISTING MASONRY
EXISTING METAL
PANEL
8"
ALUMINUM BACKER PANEL
PAINTED BM - ROCKY COAST
(8.0")
- PIN MOUNTED TO FACADE
- LEXAN BACKER
• LED LIGHTING
•STAINLESS STEEL FACES
& RETURNS
2'-9"
4'-1"
(49.0") (33.0")
PIN MOUNTED TO BACKER PANEL
BETWEEN METAL.
w/1" STANDOFFS
POWER SUPPLY
• WEEP HOLES
8"
(8.0")
X
Signature)
Side View
6/2/2022
20
BRATTLE
COMING S
Signed Letter of Approval
Harvard Collection, LLC, Clo Regency Centers Corp.,
On behalf of the
_ 1,
(Building / Company)
John Fitzpatrick
_ approve of the following exterior signs, design, &
(Building Owner Name)
pricing to be produced and installed by Boston Building Wraps within the next few months.
(Following permit approval)
We approve of the attached above to be installed onto our building located at
Cambridge
MA
20 Brattle Street.,
(Street Address)
(State)
HARVARD COLLECTION LLO
a Delaware limited liability company
Regency Centers, L.P.,
a Delaware limited partnership
Its: Managing Member
Regency Centers Corporation,
By:
a Florida corporation
Its: General Partner
X
(Signature)
Vice President, Project Management
6/2/2022
Sign 1: $11,900 (T)
Custom Fabricated Internally LED Lit Blade Sign (24 Sq Ft | Approx. 200 Pounds)
STENCIL CUT OUT
LETTERS - LED LIT
(18"w x 1.75"h)
2" FRAME
(typical)
shee
THE ABBOT
THE ABBOT
FABRICATED ALUMINUM
COLOR TO BE PROVIDED BY RC.
Office
Office
(21.7)
MILKY WHITE LEXA
Logo 1
Logo 1
ACES - LED LI
BACK OF SIGN
1-93/4"
Office
Office
2" DEEP BACKER PANEL
(21.7)
Logo 2"
Logo 2
21"w x 33"h
7'-0"
6'-5"
PAINTED BM - ROCKY COAST
(84.0")
(77.0")
PRINT/CUT VINYL
1'-9 3/4"
TENANT LOGOS
(21.7")
CENTRAL ROCK GYM
CENTRAL RECK GYM
11 3/4*
117"
1'-8"
2'-0"
(24.0")
Front View
1-9"
2'-0"
(24.0")
(21.0")
(2.b")
- 2. FRONT SIGN
1'-10 ½"
(22.5")
LECTRICAL FEEI
TO BLADE SIC
2'-0"
-
(24.0")
- EASED EDGES
(typical)
EXISTING MASONRY
Top View
im STAINLESS STE
TTERS - NON-I
ABRICATED ALUMINU
LADE SIC
- MOUNTING BRACKET
EXISTING METAL
PANEL
1/2" THREADED ROD
ANCHORS W/HILTY
(8,0")
1/2" THREADED ROD ANCHORS
- 2" DEEP FABRICATED
W/HILTY ADHESIVE
BACKER PANEL
2'-9"
FINAL QUANTITY AND LOCATIONS TBD
490% 330)
PIN MOUNTED TO
BASED ON FINAL STRUCTURAL DRAWING
BACKER PANEL
8"
Connection Detail
POWER SUPPLY
(8,0)
- WEEP HOLES
**MOUNTED FLUSH WITH BOTTOM OF METAL PANEL***
X
Side View
(Signature)
6/2/2022
Sign 2: $7,700 (T)
Custom Fabricated Internally LED Lit Front Sign (7.35 Sq Ft | Approx. 210 Pounds)
20
BRATTLE
Perspective View
5'-4"
(64.0")
2-6
CONDUIT-
ELECTRICAL FEEDS
INTO BLADE SIGN
CLEAR AREA
2" DEEP ALUMINUM
2'-8"
2-9" BETWEEN EXISTING
HACKER PANEU
METAL GROOVES
(32.0")
(33.0")
PAINTED TO MATCH
IN SIGN BAND
BM - ROCKY COAST
20
2" DEEP FABRICATED
STAINLESS STEEL LETTERS
BRUSH BRONZE RETURNS
BRATTLE
WHITE FACES
1%
(60.9*)
Front View
EXISTING MASONRY
EXISTING METAL
PANEL
8"
ALUMINUM BACKER PANEL
PAINTED BM - ROCKY COAST
(8.0")
- PIN MOUNTED TO FACADE
LEXAN BACKER
LED LIGHTING
STAINLESS STEEL FACES
& RETURNS
2'-9"
4'-1"
(49.0") (33.0")
- PIN MOUNTED TO BACKER PANEL
w/1" STANDOFFS
POWER SUPPLY
WEEP HOLES
8"
(8.0")
X_
(Signature)
Side View
6/2/2022
20
BRATTLE
302 laT
COMING S
CURB
e17 850 9618
lal
20
BRATTLE
B
CITY of BOSTON
Martin J. Walsh, Mayor
MATTOCKS-HIGGINS AFFIDAVIT OF WORKPLACE SAFETY
1 Joseph A. Correia I do hereby declare the following to be true and
accurate to the best of my knowledge.
I.
Occupational Safety and Health Administration (OSHA) « has not issued / - has issued
any notice or violation against my company, as a sole proprietorship, limited partnership, and/or limited
liability partnership/corporation, and/or any affiliated business or subsidiary of which I am an owner,
manager, officer and/or director in the last five (5) years.
If you selected "has issued", please disclose the following information:
Date of Violation
Company
Address of Violation
Total Fines, if any
Serious
Check if:
Repeat
_Failure to Abate
_ Willful
Named violation:
Date of Violation_
Company
Address of Violation
Total Fines, if any.
Serious
Repeat
_Failure to Abate
Check if:
_ Willful
Named violation:
**Attach additional pages if necessary
If any violations are categorized as Willful or Repeat, affidavit must be accompanied by a copy of the Site
Safety Plan for the project seeking permit.
Is the company currently on the OSHA Severe Violator Enforcement Program (SVEP) Log?
- Yes
& No
Companies in the SEP are not eligible to receive a permit from the City of Boston
•89
Company's Experience Modification Rating: _
Available from the MA Workers Compensation Rating and Inspection Bureau
The Licensed Contractor must disclose any subcontractor's OSHA violation history or SVEP designation
to the permit reviewing department.
Signed under penalties of perjury:
03.302022
The Permit Reviewing Authority, or designee, shall have the discretion to issue a stop work order
for any open permits and/or deny the issuance of a permit due to failure to disclose any and all
OSHA violations or demonstrated history of unsafe, hazardous or dangerous practices.
Published October 18, 2017
The Commonwealth of Massachusetts
Department of Industrial Accidents
Office of Investigations
Lafayette City Center
2 Avenue de Lafayette, Boston, MA 02111
www.mass.gov/dia
NO THINEY
Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers
Please Print Legibly
Applicant Information
Boston Building Wraps, Inc.
Name (Business/Organization/Individual):_
Address: 458 Main Street
Phone #: (781) 799 - 5051
Wilmington, MA 01887
City/State/Zip:
Are you an employer? Check the appropriate box:
Type of project (required):
4. • 1 am a general contractor and 1
1.O 1am a employer with 10
6. • New construction
have hired the sub-contractors
employees (full and/or part-time).*
7. • Remodeling
listed on the attached sheet.
2. • 1 am a sole proprietor or partner-
These sub-contractors have
8.
• • Demolition
ship and have no employees
employees and have workers'
working for me in any capacity.
9. Building addition
comp. insurance.!
[No workers' comp. insurance
10. Electrical repairs or additions
5. L
J We are a corporation and its
required.]
officers have exercised their
11.D Plumbing repairs or additions
3. L 1 am a homeowner doing all work
right of exemption per MGL
12. Roof repairs
myself. [No workers' comp.
c. 152, §1(4), and we have no
insurance required.] *
13.D Other
employees. [No workers'
comp. insurance required.]
I am an employer that is providing workers' compensation insurance for my employees. Below is the policy and job site
information.
Liberty Mutual Insurance Company
Insurance Company Name:_
04/11/2022
Expiration Date:
Policy # or Self-ins. Lic. #:_ XW059693930
City/state/zip: Cambridae, MA 02138
Job Site Address: 20 Brattle St.
Attach a copy of the workers' compensation policy declaration page (showing the policy number and expiration date).
Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a
fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine
of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of
Investigations of the DIA for insurance coverage verification.
penalties of perjury that the information provided above is true and correct.
I do hereby certify und
Date:
03/30/2002
Signature:
(781) 7
Phone #:
Official use only. Do not write in this area, to be completed by city or town official.
Permit/License #
City or Town:
Issuing Authority (check one):
i Board of Health 2 Building Department 3OCity/Town Clerk 4. Electrical Inspector 5 Plumbing
Inspector 6.OJOther
Contact Person:
Phone #:
6'-0"
(72.0")
(230.2")
19-2 4"
BATTLE.
(147.6")
12'-3 5/8"
(175.2")
14'-7 1/4"
Project: 1121_67 The Abbot - 20 Brattle St - Exterior Signage
LOCATION
BLADE SIGN
for a protruding sign
(Minimum of 8ft clearance
reproduction. Both parties agree that authorization to proceed with project whether per written estimate or verbal authorization will act as User's naming of BBWinc.; as vendor for said services. User does not have a proac
In the event of Termination. Either party may terminate the contract at any time through written request. The User shall upon termination pay BBWInc. all unpaid amounts due for Services completed prior to notice of termination.
LOCATION
FRONT SIGN
Work, but User may not seek to mislead others that Work was created by anyone other than BBWinc. User request of BBWinc. to create project relevant drawings, sketches and/or artwork includes only the final, deliverable art, and not any preliminary Work or sketches.
ctive duty to display BBWinc.'s name together with
Boston Building Wraps Inc Right to Authorship Credit. Client and/or Commissioner, hereafter referred to as User, and Boston Building Wraps Inc. hereafter referred to as BBWinc., agree that when asked, User must properly identify BBWInc. as the creator of artwork for future
Artist:
Client:
1200
Revision #
Sale: 1/8"= 1'0"
Date: 05/12/2022
Project Location:
Derek B.
[phone removed]
20 Brattle St
John Fitzpatrick
General Notes
Vienna, VA 22182
BOSTON
WRAPS:
Cambridge, MA 02138
1919 Gallows Road, Suite 1000
EX1
[email removed]
4000801
Drawing No.
(typical)
2" FRAME
7'-0"
6'-5"
(84.0") (77.0")
Top View
(2.0")
Front View
2'-0"
(24.0")
(20.0")
Office
Office
Logo 2
Logo 1
CENTRAL ROCK GYM
THE ABBOT
- 2-0+
(24.0")
- (2i0)
Office
Office
Logo 1
Logo 2
CENTRAL ROCK GYM
THE ABBOT
2'-0"
(22.5")
1-10 ½"
+5.0
(24.0") -
1-9 344
11 3/4"
(21.7")
(21.7)
1-9 3/4"
(7)
1'-9 3/4"
(21.7)
21"w x 33"h
(typical)
(18"w x 1.75"h)
BACK OF SIGN
TENANT LOGOS
FACES - LED LIT
PRINT/CUT VINYL
LETTERS - LED LIT
STENCIL CUT OUT
EASED EDGES
- 2. FRONT SIGN
MILKY WHITE LEXAN
2" DEEP BACKER PANEL
FABRICATED ALUMINUM
PAINTED BM - ROCKY COAST
COLOR TO BE PROVIDED BY RC.
4'-1"
8"'
2'-9"
(8.0")
(8,0)
(49.0") (33.0")
Side View
Project: 1121_67 The Abbot - 20 Brattle St - Exterior Signage #1
Connection Detail
In the event of Termination. Either party may terminate the contract at any time through written request. The User shall upon termination pay BBWInc, all unpaid amounts due for Services completed prior to notice of termination.
PANEL
FINAL QUANTITY AND LOCATIONS TBD
BLADE SIGN
WEEP HOLES
W/HILTY ADHESIVE
BASED ON FINAL STRUCTURAL DRAWING
BACKER PANEL
POWER SUPPLY
EXISTING METAL
PIN MOUNTED TO
EXISTING MASONRY
MOUNTING BRACKET
2 DEEP FARE ATED
FABRICATED ALUMINUM
-MOUNTED FLUSH WITH BOTTOM OF METAL PANEL***
1/2" THREADED ROD ANCHORS
Work, but User may not seek to mislead others that Work was created by anyone other than BBWInc. User request of BBWinc, to create project relevant drawings, sketches and/or artwork includes only the final, deliverable art, and not any preliminary Work or sketches.
Artist:
Client:
24 sf
Revision #
Scale: 1/2" = 1'0"
Date: 05/23/2022
Project Location:
1. BLADE SIGN
Internally LED Lit
Derek B.
Custom Fabricated
[phone removed]
General Notes
John Fitzpatrick
DING
BOSTON
WRAPS!
Vienna, VA 22182
Cam 20 gra. MA 02138
1919 Gallows Road, Suite 000
B1
[email removed]
1234060801
Drawing No.
Front View
Perspective View
BACKER PANEL
2" DEEP ALUMINUM
2" DEEP FABRICATED
ELECTRICAL FEEDS
INTO BLADE SIGN
STAINLESS STEEL LETTERS
CONDUIT
BRUSH BRONZE RETURNS
WHITE FACES
BM - ROCKY COAST
PAINTED TO MATCH
Sin
=
(1.5")
20
(30.2")
BRATTLE
20
5'-4"
(60.9")
(64.0")
5'-0 7/8*
4'-1"
BRATTLE
Project: 1121_67 The Abbot - 20 Brattle St - Exterior Signage #2
(1.5")
ão
50
2'-9"
(49.0") (33.0")
(8.0")
Side View
BETWEEN METAL
2'-8"
(32.0")
In the event of Termination. Either party may terminate the contract at any time through written request. The User shall upon termination pay BBWInc. all unpaid amounts due for Services completed prior to notice of termination.
2'-9"
(33.0")
PANEL
& RETURNS
WEEP HOLES
LED LIGHTING
LEXAN BACKER
POWER SUPPLY
EXISTING METAL
w/1" STANDOFFS
EXISTING MASONRY
CLEAR AREA
IN SIGN BAND
METAL GROOVES
STAINLESS STEEL FACES
BETWEEN EXISTING
Work, but User may not seek to mislead others that Work was created by anyone other than BBWInc. User request of BBWInc. to create project relevant drawings, sketches and/or artwork includes only the final, deliverable art, and not any preliminary Work or sketches.
PIN MOUNTED TO FACADE
ALUMINUM BACKER PANEL
reproduction. Both parties agree that authorization to proceed with project whether per written estimate or verbal authorization will act as User's naming of BBWInc.; as vendor for said services. User does not have a proactive duty to display BBWinc.'s name together wit
PAINTED BM - ROCKY COAST
Boston Building Wraps Inc Right to Authorship Credit. Client and/or Commissioner, hereafter referred to as User, and Boston Building Wraps Inc. hereafter referred to as BBWinc. ,agree that when asked, User must properly identify BBWInc. as the creator of artwork for future
PIN MOUNTED TO BACKER PANEL
Artist:
Client:
7.35 sf
Revision #
Reference Image
Scale: 1 = 1'0"
Date: 05/23/2022
Project Location:
2. FRONT SIGN
Internally LED Lit
Derek B.
[phone removed]
Custom Fabricated
John Fitzpatrick
General Notes
Vienna, VA 22182
BOSTON
WRAPS!
Cam 20 graMA 02138
1919 Gallows Road, Suite 1000
F1
[email removed]
Drawing No.
20
BRATTLE
COMING SI
[phone removed]
20
BRATTLE